American Dynamics AD1020-1541 Installation And Operating Instructions Manual Download Page 11

INSTALLATION AND
OPERATING INSTRUCTIONS

1020 SERIES 30/60-WATT LED INFARED ILLUMINATOR

8000-1794-01, REV. A

11

Declarations

Regulatory Compliance

Emissions .............................. 47 CFR, Part 15

ETS 300 330

ETS 300 683

Safety .................................... EN 60 950

FCC COMPLIANCE:

 This equipment complies with Part

15 of the FCC rules for intentional radiators and Class A
digital devices when installed and used in accordance with the
instruction manual. Following these rules provides reasonable
protection against harmful interference from equipment
operated in a commercial area. This equipment should not be
installed in a residential area as it can radiate radio frequency
energy that could interfere with radio communications, a
situation the user would have to fix at their own expense.

EQUIPMENT MODIFICATION CAUTION:

 Equipment

changes or modifications not expressly approved by
Sensormatic Electronics Corporation, the party responsible for
FCC compliance, could void the user's authority to operate the
equipment and could create a hazardous condition.

Other Declarations

WARRANTY DISCLAIMER:

 Sensormatic Electronics

Corporation makes no representation or warranty with respect
to the contents hereof and specifically disclaims any implied
warranties of merchantability or fitness for any particular
purpose. Further, Sensormatic Electronics Corporation
reserves the right to revise this publication and make changes
from time to time in the content hereof without obligation of
Sensormatic Electronics Corporation to notify any person of
such revision or changes.

LIMITED RIGHTS NOTICE:

 For units of the Department

of Defense, all documentation and manuals were developed at
private expense and no part of it was developed using
Government Funds. The restrictions governing the use and
disclosure of technical data marked with this legend are set
forth in the definition of "limited rights" in paragraph (a) (15)
of the clause of DFARS 252.227.7013. Unpublished - rights
reserved under the Copyright Laws of the United States.

Summary of Contents for AD1020-1541

Page 1: ...a license for use on a single system Information furnished by AMERICAN DYNAMICS is believed to be accurate and reliable However no responsibility is assumed by AMERICAN DYNAMICS for its use nor for an...

Page 2: ...oduct for service Do not attempt to service this product yourself Opening or removing covers may expose you to dangerous voltages or other hazards Refer all servicing to qualified personnel Descriptio...

Page 3: ...Before installation become familiar with all the special features and warnings associated with this equipment Once installation is complete store this document in a safe convenient location for futur...

Page 4: ...ponents B C and D of the liquid tight hub Figure 3 into an appropriate pass through Note Hub B fits through the O ring D on the outside of the enclosure and is secured by nut C on the inside of the en...

Page 5: ...osure by means of the double sided tape provided Tighten the bushing Caution If necessary trim the MOV surge suppressor leads to keep them as short as possible After the leads are connected to the ter...

Page 6: ...he S V terminals Connect the proper input supply voltage 120Vac or 230Vac to the input terminals Confirm a reading of 13 5 0 1Vdc If necessary adjust the Voltage Adjustment Potentiometer VR51 Adjustin...

Page 7: ...0 3060PSA Power Supply uses remote sensing to maintain a constant voltage at the Illuminator A 4 wire configuration between the power supply and the Illuminator maintains the correct load voltage over...

Page 8: ...0 watt illuminator AWG Distance 12 0m 30 5m 0 100 14 0m 22 9m 0 75 16 0m 15 2m 0 50 Troubleshooting PROBLEM POSSIBLE CAUSE SOLUTION Lamp does not come on No 13 5 Vdc to Lamp Check 120 Vac or 230 Vac s...

Page 9: ...020 SERIES 30 60 WATT LED INFARED ILLUMINATOR 8000 1794 01 REV A 9 Dimensions Figure 8 1020 series Illuminator dimensions 30 60 Watt model 65mm 2 56 182mm 7 17 127mm 5 0 2mm 08 21mm 83 6mm threaded ho...

Page 10: ...range 22m 72ft 20m 66ft 20m 66ft 55m 180ft 42m 138ft 35m 115ft ELECTRICAL Operating Voltage 13 5Vdc 13 5Vdc 13 5Vdc 13 5Vdc 13 5Vdc 13 5Vdc Current Amps 2 5A 2 5A 2 5A 4 6A 4 6A 4 6A ALL UNITS Service...

Page 11: ...sible for FCC compliance could void the user s authority to operate the equipment and could create a hazardous condition Other Declarations WARRANTY DISCLAIMER Sensormatic Electronics Corporation make...