48
C. L.E.D. CODES
1. Display Codes
A
SLOPE FACTOR
ALL REV
ALWAYS REVERSING
ANTI WRINKL dELAY TIME
ANTI-WRINKLE DELAY TIME
ANTI WRINKL GUARd ACTIVE
ANTI-WRINKLE PROGRAM ACTIVE
ANTI WRINKL GUARd ON TIME
ANTI-WRINKLE GUARD ON TIME
AUTO CYCLE
AUTOMATIC MODE
b
HEAT LOSS (OFF SET) FACTOR
bURNER CONTROL FAIL
GAS ONLY ... POWER (24VAC) IS NOT EVIDENT AT GAS VALVE
bURNER FLAME FAIL
NO BURNER FLAME SENSED
bURNER SAFETY FAIL
GAS/ELECTRIC ONLY ... BURNER/OVEN OPEN HI-LIMIT CIRCUIT
bUZZ
BUZZER (TONE)
bUZZ TIME
BUZ TIME
ºCEL
DEGREE IN CELSIUS
CHECK MAIN FUSE
MAIN FUSE FAILURE
CLEAN LINT
PROMPT TO CLEAN LINT SCREEN, DRYER CYCLE LOCKOUT
COOL
COOL DOWN CYCLE IN PROGRESS
COOL TIME__M
COOL DOWN TIME
COOL TEMP___
COOL DOWN TEMPERATURE
CYCLEA
PREPROGRAMMED CYCLE A
CYCLEb
PREPROGRAMMED CYCLE B
CYCLEC
PREPROGRAMMED CYCLE C
CYCLEd
PREPROGRAMMED CYCLE D
CYCLEE
PREPROGRAMMED CYCLE E
CYCLEF
PREPROGRAMMED CYCLE F
dONE
DRYING or COOLING CYCLE COMPLETE OR DRYER IN ANTI-WRINKLE MODE
dRYING
DRYING CYCLE IN PROGRESS
dRY LEVEL___
DRYNESS LEVEL (PERCENTAGE OF EXTRACTION) (NUMERICAL VALUE)
dRY TEMP F___
DRYING TEMPERATURE
dRY TIME__M
LENGTH OF DRYING CYCLE
dRUM SAFETY FAIL
TUMBLER (BASKET) HI-LIMIT CIRCUIT IS OPEN
ELAPSE TIME___MIN
CYCLE DISPLAY TIME
ELECTRIC
SPECIFIC HEAT TYPE OF DRYER ... ELECTRICALLY HEATED
F
FABRIC TEMPERATURE
ºFAR
DEGREE IN FAHRENHEIT
FLASH
FLASH DISPLAY ACTIVE
GAS
SPECIFIC HEAT TYPE OF DRYER ... GAS HEATED
HOT
INDICATES AN OVERHEAT CONDITION
LINT dOOR
LINT DRAWER / DOOR CIRCUIT IS OPEN OR FAULT IN THE A.C. SWITCH CIRCUIT
LINT COUNT
DRYING CYCLES RANGE FROM 1-10 CYCLES BEFORE CLEAN LINT DISPLAY
__M REMAIN
CYCLE DISPLAY TIME
MAIN dOOR
DOOR CIRCUIT IS OPEN OR FAULT IN THE A.C. DOOR SWITCH CIRCUIT
MANUAL CYCLE
MANUAL MODE
MAX ANTI WRINKL GUARd
MAXIMUM GUARD TIME
NFLASH
FLASH DISPLAY NOT ACTIVE
NoAIR FLOW
SAIL SWITCH OPEN
NoANTI WRINKL GUARd
ANTI-WRINKLE PROGRAM IS NOT ACTIVE
NoBUZZ
NO BUZZER (TONE)
NoHEAT
GAS ONLY ... IGNITION ATTEMPT FAILURE
NoREV
NO REVERSE
No ROTATE SENSOR
NO ROTATIONAL SENSOR SELECTED
PROGRM
PROGRAM MODE
REAdY
NO CYCLE IN PROGRESS
ROTATE SENSOR ACTIVE
ROTATIONAL SENSOR SELECTED
ROTATE SENSOR FAIL
ROTATIONAL SENSOR CIRCUIT FAILURE
__RPM
MONITORS TUMBLER (BASKET) RPM WITH ROTATIONAL SENSOR CIRCUIT ACTIVE
SAIL SWITCH FAIL
GAS/ELECTRIC ONLY. ATTEMPT MADE TO START DRYER WITH SAIL SWITCH
DISABLED IN CLOSED POSITION
SELREV.
SELECT REVERSE
SPIN TIME
SPIN TIME
START GUARd
START ANTI WRINKLE GUARD CYCLE
STEAM
SPECIFIC HEAT TYPE OF DRYER ... STEAM HEATED
STOP TIME
STOP TIME
TEMP SENSOR FAIL CHECK
FAULT IN M.P. HEAT SENSING CIRCUIT
TEMP SENSOR FUSE