24
IMPORTANT:
The dryer
must be
connected to the electric supply shown on the data label that is
affixed to the left side panel/wall area behind the control door. In the case of 208
VAC or 230/240 VAC, the supply voltage must match the electric service
specifications of the data label
exactly
.
WARNING: 208 VAC AND 230/240 VAC ARE NOT THE SAME.
Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC
reserves the right to make changes in specifications at any time without notice or
obligation.
MLE-130 II (72 Kw Electric)
Reversing, 3ø
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT
: 208 VAC AND 230/240 VAC
ARE NOT THE SAME
.
When ordering,
specify
exact voltage
.
NOTES
:
A.
B.
C.
When fuses are used they
must be
dual element, time delay, current limiting,
class RK1 or RK5
ONLY
. Calculate/determine correct fuse value, by
applying either local and/or National Electrical Codes to listed appliance amp
draw data.
Circuit breakers are thermal-magnetic (industrial) type
ONLY
. For others,
calculate/verify correct breaker size according to appliance amp draw rating
and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers
must be
3-pole type.
OVEN SIZE
(Kw)
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
60 Hz
50 Hz
72
208
3ø
3
214
214
72
230/240
3ø
3
189
189
72
380-400
3ø
3/4
---
114
72
416
3ø
3/4
---
107
72
480
3ø
3/4
94
---
72
575
3ø
3
79
---