2. Technical Gas Data
a. Gas Specifications
b. Gas Connections:
Inlet connection ------------ 3/4-inch N.P.T.
Inlet supply size ------------ 3/4-inch N.P.T. (minimum)
Btu/hr input (per dryer) --- 200,000
1) Natural Gas
Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressure
must
be
consistent between a minimum of 6.0 inches and a maximum of 12.0 inches water column
(W.C.) pressure.
2) Liquid Propane (L.P.) Gas
Dryers made for use with L.P. (liquid propane) gas have the gas valve's internal pressure regulator
blocked open so that the gas pressure
must be
regulated upstream of the dryer. The pressure
measured at each gas valve pressure tap
must be
a consistent 11.0 inches water column (W.C.).
There is no regulator or regulation provided in an L.P. dryer. The water column (W.C.) pressure
must
be
regulated at the source (L.P. tank) or an external regulator
must be
added to each dryer.
* D.M.S. (Drill Material Size of equivalents are as follows:)
Natural Gas ................... #29 = .1360"
Liquid Propane Gas ....... #47 = .0785"