8
SECTION III
INSTALLATION PROCEDURES
Installation should be performed by competent technicians in accordance with local and state codes. In the
absence of these codes, the installation
must conform
to applicable NATIONAL ELECTRIC CODE ANSI/
NFPA NO. 70-LATEST EDITION, or in Canada, the CANADIAN ELECTRICAL CODES PARTS 1 & 2
CSA C22.1-1990 or LATEST EDITION.
A. REASSEMBLY OF DRYER
IMPORTANT
: Always keep the tumbler (basket) section of the dryer in an upright position when
moving it
.
1. Reassembly Instructions for Dryer Shipped in Two (2) Pieces
In this method of shipment, the tumbler section and the tumbler base section are shipped as one unit and the
heat console section is the second.
a. Reassemble Tumbler (Basket) and Tumbler (Basket) Base Section To The Heat Console Section
Move both pieces into position by lifting them with cables through the eyebolts located at the top of each
of the two sections. These pieces may also be moved into place with a fork (lift) truck by lifting the pieces
from underneath. The tumbler and tumbler base section weighs about 6,400 pounds (2,903 kg) and the
heat console section weighs about 4,100 pounds (1,860 kg). Once the sections are in position, the seven
(7) clearance holes on the tumbler (basket) base section (four [4] in the front and three [3] in the rear)
must be
aligned with the seven (7) #3/8-16 tapped holes in the heat console section. Use the three (3)
#8-16 x 2” long bolts along with the tapered shims supplied to bolt the two sections together.
b. Reattach The Control Pendant Arm
Position the control pendant arm to the top front of the heat console section by aligning the clearance holes
in the arm with the 1/4-20 tapped holes on the top of the heat console section. Use the 1/4-20 x 3” long
bolts supplied with the machine to attach the arm to the console.
c. Reconnect The Internal Air, Electric Connections, and Water Connections (refer to
page 12 through
page 18
).