background image

American DJ

®

  -  www.americandj.com  - X-Color LED™ Instruction Manual Page 6

American DJ

®

  -  www.americandj.com  - X-Color LED™ Instruction Manual Page 5

Power Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your American DJ

®

 

X-Color LED.™ The American DJ

®

 X-Color LED

 is available in a 120v 

and 220v version. Because line voltage may vary from venue to venue, 
you should be sure your unit voltage matches the wall outlet voltage 

before attempting to operate you fixture.  Also be sure to only use the 

included I.E.C. power cable supplied with the unit, this cable matches 
the voltage and current requirements of the unit.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 
communication  between  intelligent  fixtures  and  controllers. 

A  DMX 

controller sends DMX data instructions from the controller to the fix

-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX  Linking: 

DMX  is  a  language  allowing  all  makes  and  models 

of  different  manufactures  to  be  linked  together  and  operate  from  a 

single  controller,  as  long  as  all  fixtures  and  the  controller  are  DMX 

compliant.

  To  ensure  proper  DMX  data  transmission,  when  using 

several DMX fixtures try to use the shortest cable path possible. The 
order in which fixtures are connected in a DMX line does not influence 
the DMX addressing. For example; a fixture assigned a DMX address 
of 1 may be placed anywhere in a DMX line, at the beginning, at the 
end, or anywhere in the middle. Therefore, the first fixture controlled 
by the controller could be the last fixture in the chain. When a fixture 
is  assigned  a  DMX  address  of  1,  the  DMX  controller  knows  to  send 
DATA assigned to address 1 to that unit, no matter where it is located 
in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX 

and Master/Slave Operation): 

The X-Color LED™ 

can  be  controlled  via  DMX-512  protocol.  The  X-
Color LED™ is be a three channel DMX unit. The 
DMX  address  is  set  electronically  using  the  con-
trols  on  the  rear  panel  of  the  unit.  Your  unit  and 
your DMX controller require a approved DMX-512 
110 Ohm Data cable for data input and data output 
(Figure 1). We recommend Accu-Cable DMX cables. If you are making 

 X-Color LED™ 

 

                                           Set Up

Figure 1

your own cables, be sure to use standard 110-120 Ohm shielded cable 
(This  cable  may  be  purchased  at  almost  all  professional  sound  and 
lighting stores). Your cables should be made with a male and female 
XLR connector on either end of the cable. Also remember that DMX 
cable must be daisy chained and cannot be split.

 X-Color LED™ 

 

 

 

                       Set Up

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

Summary of Contents for X-Color LED

Page 1: ...Introduction The X Color LED is a three channel DMX intelligent color changing LED fixture The X Color LED can operate as a stand alone fixture or in a Master Slave configuration The X Color LED is a...

Page 2: ...d has been spilled into the appliance B The appliance has been exposed to rain or water C The appliance does not appear to operate normally or exhibits a marked change in performance X Color LED Safet...

Page 3: ...is set electronically using the con trols on the rear panel of the unit Your unit and your DMX controller require a approved DMX 512 110 Ohm Data cable for data input and data output Figure 1 We reco...

Page 4: ...rsion Conductor 5 Pin XLR Male In 3 Pin XLR Female Out Pin 1 Pin 5 Do Not Use Pin 4 Do Not Use Pin 3 Pin 2 Pin 1 Pin 3 Pin 2 Not Used Not Used Data True signal Data Compliment signal Ground Shield 3 P...

Page 5: ...mode select No and press Enter LED With this function you can have the LED display turn off after 10 seconds 1 Tap the MENU button until LED is displayed press ENTER 2 The display will show either ON...

Page 6: ...al needs 1 The X Color LED is a three DMX channel DMX fixture See page 13 for detailed description of the DMX traits 2 To control your fixture in DMX mode follow the set up procedures on pages 5 7 as...

Page 7: ...or at the last fixture 2 On the Master unit find your desired show and set that show by pressiing the ENTER button 3 On the slave units tap the MENU button until SLND is dis played select your desired...

Page 8: ...s are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or fitness shall apply to this product after sai...

Page 9: ...American DJ www americandj com X Color LED Instruction Manual Page 17 American DJ www americandj com X Color LED Instruction Manual Page 18 X Color LED Notes X Color LED Notes...

Page 10: ...el X Color LED Voltage 100 240V 50Hz 60Hz Auto Sensing Power Consumption 31W Beam Angle 13 Degrees Dimensions 7 87 L x 6 W x 6 7 H 194mm x 200mm x 197mm Colors RGB White Weight 5 3 Lbs 3 0 kgs Fuse 2...

Reviews: