background image

American DJ® 

LOS ANGELES, CA. 90058

The  Tempest ll ™ is now Linkable  with Master / Slave capability!  To use this function set the MAS-
TER unit dipswitch #10 on. Then connect  with the XLR Cable using the Female XLR to the second
unit input Male XLR , Turn all dipswitches off on the SLAVE unit. and it will respond the same as the
first unit.
In addition you can select the program you want by using a DMX 512 Controller. The values needed
are in Chart ONE below.The  Tempest ll ™ uses 1 channel to control program selection. Please
select the starting address by using the dip switches. 

CHART ONE

Value 

Result

0-7

Blackout

8-15

Program 1 

16-23

Program 2

24-31

Program 3

32-39

Program 4

40-47

Program 5

48-55

Program 6

56-63

Program 7

64-71

Program 8

72-79

Program 9

80-87

Program 10

88-95

Program 11

96-103

Program 12

104-111

Program 13

112-119

Program 14

120-127

Program 15

128-135

Program 16

136-143

Program 17

144-151

Program 18

152-159

Program 19

160-167

Program 20 

168-175

Program 21 

176-183

Program 22 

184-191

Program 23 

192-199

Program 24 

200-207

Program 25 

208-215

Program 26 

216-223

Program 27 

224-231

Program 28 

232-255

Random
Programs

DMX CHANNEL

1 2 3

5

4

7

9 10

8

6

ON

1     4    16   64  256

2     8    32  128

TEMPEST II™ Instructions CONT.

Each # above has an ADDRESS based on binary code.
#1 ADDRESS is 1
#2      “

“   2

#3      “            “   4
#4      “            “   8
#5      “

“   16

#6      “

“   32

#7      “            “   64
#8      “

“   128

#9      “

“   256

#10    is not used with DMX but  to select Master / Slave
ALWAYS SET THE ADDRESS ONE LESS THAN THE
CHANNEL WANTED. 

You set the ADDRESS wanted by COMBINING the
Dipswitches.

EXAMPLE:
Set ADDRESS at  0  to start at CHANNEL 1 
( all Dipswitches OFF)
Set ADDRESS for  21      Set ADDRESS for  201
to start at CHANNEL 22    to start at CHANNEL 202
Dipswitches # 1 =1           Dipswitches # 1 = 1

3 = 4

4 = 8

  5 = 16

7 = 64

= 21

8 = 128

=  201

PIN CONFIGURATION

DATA IN

XLR MALE SOCKET

3 Data +

Data - 2

1 Ground