background image

©

American DJ Supply

®

  -  www.americandj.com  - Mighty Scan™ Instruction Manual Page 10

©

American DJ Supply

®

  -  www.americandj.com  - Mighty Scan™ Instruction Manual Page 9

 Mighty Scan™  

 

 

 

 

 

 Set Up

 

are no more than 16 units in a Master-Slave configuration, how- 

 

ever only one unit may have the “Master - Head 1” dip switch set- 

 

ting.

This  chart  details  the  Master/Slave  dip  switch  setting  for  Master/
Slave configuration for four units. Use these dip switch setting when 
you will be using two or more fixtures in a Master/Slave configuration. 
The “Master - Head 1” settings should only be used once. 

Universal  DMX  Control: 

This  function  allows  you  to  use  a  univer-

sal  DMX  512  controller  such  as  the  American  DJ

®

  DMX  Operator™ 

or  Show  Designer™  to  control  lamp  intensity,  color,  and  gobo. 
Operating  through  a  DMX  controller  allows  the  freedom  to  create 
unique programs tailored to one’s individual needs.

1.   The Mighty Scan™ uses three DMX channels. Channel one con- 
      trols the lamp intensity (dimmer), channel two controls the color  
      selection, and channel three control the gobo wheel. Please refer  
      to page 16 for a detailed description of the DMX traits.
2.   To control your fixture in DMX mode, follow the unit set-up proce- 
      dures beginning on page 10 as well as the set-up specifications  
      that are included with your DMX controller. 
3.   Use the controller’s faders to control the various DMX fixture    
      traits.
4.   This will allow you to create custom programs.
5.   When using a DMX controller and setting up for DMX operation.  
6.   For help operating in DMX operation consult the manual included  
      with your DMX controller.
7.   For longer cable runs (more than a 100 feet) use a terminator on  
      the last fixture in you DMX chain.

 Mighty Scan™  

 

 

 

 

      Operation

Power Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your American DJ

®

 

Mighty Scan.™ Because line voltage may vary from venue to venue, 
you should be sure your unit voltage matches the wall outlet voltage 
before attempting to operate you fixture.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 
and controllers. A DMX controller sends DMX data instructions from 
the controller to the fixture. DMX data is sent as serial data that trav-
els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-
minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 

DMX Linking:

 DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a sin-
gle controller, as long as all fixtures and the controller are DMX com-
pliant. To ensure proper DMX data transmission, when using several 
DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 
may be placed anywhere in a DMX line, at the beginning, at the end, 
or anywhere in the middle. When a fixture is assigned a DMX address 
of 1, the DMX controller knows to send DATA assigned to address 1 
to that unit, no matter where it is located in the DMX chain.

 

Dip-switches in DMX mode: 

This unit uses dip switches to assign 

a DMX address. Each dip switch represents a binary value. 
Dip Switch 1 address equals 2 

 

Dip Switch 2 address equals 3 

 

Dip Switch 3 address equals 5 

 

Dip Switch 4 address equals 9 
Dip Switch 5 address equals 17 

 

Dip Switch 6 address equals 33
Dip Switch 7 address equals 65 

 

Dip Switch 8 address equals 129
Dip Switch 9 address equals 257
  

ON

1

9

8

7

6

5

4

3

2

10

129

3

9

33

257

65

17

5

2

SP

DMX CHANNEL

ON

1

9

8

7

6

5

4

3

2

10

All Slaves

ON

1

9

8

7

6

5

4

3

2

10

Master - Head 1

Summary of Contents for Mighty Scan

Page 1: ...best used in multiples of four This unit use a separate color and gobo wheel with 20 colors plus white and 20 gobos plus spot This piece is best used with a fog or haze machine to enhance the beam ou...

Page 2: ...and fire in case of an internal short Disconnect from main power before making any type of connection Do not remove the cover under any conditions There are no user serviceable parts inside Never ope...

Page 3: ...Always replace with the exact same type fuse unless other wise instructed by an authorized American DJ service technician 5 Microphone This microphone receives external low frequencies to trigger the...

Page 4: ...or longer cable runs we suggest a termina tor at the last fixture Refer to the set up procedures beginning on page 10 2 Follow the Master Slave dip switch chart on page 16 for proper dip switch settin...

Page 5: ...ce volt age in your area matches the required voltage for your American DJ Mighty Scan Because line voltage may vary from venue to venue you should be sure your unit voltage matches the wall outlet vo...

Page 6: ...unit to avoid erratic behavior A terminator is a 90 120 ohm 1 4 watt resistor which is con nected between pins 2 and 3 of a male XLR connector DATA and DATA This unit is inserted in the female XLR co...

Page 7: ...exact same type lamp and fuse unless otherwise specified by an authorized American DJ techni cian Replacing with anything other than the specified part can dam age the unit and will void the manufact...

Page 8: ...blown The fuse is located on the rear panel of the unit 3 Remove the lamp cover and be sure the lamp is seated in its socket properly Occasionally lamps become loose during ship ping be sure the lamp...

Page 9: ...lue to somewhere in between the two colors you want to split Only a pair of colors that are next to each other on the color wheel can be split For example Blue 107 and Blue 110 are a pair of colors th...

Page 10: ...y Scan Instruction Manual Page 19 American DJ Supply www americandj com Mighty Scan Instruction Manual Page 20 Dip Switch Position Dipswitches DMX Address The center numbers of this chart 1 511 repres...

Page 11: ...rts at the sole discretion of American DJ All products covered by this war ranty were manufactured after January 1 1990 and bear identifying marks to that effect E American DJ reserves the right to ma...

Reviews: