background image

ADJ Products, LLC  -  www.adj.com  - Inno Spot Elite Instruction Manual Page 9

ADJ Products, LLC  -  www.adj.com  - Inno Spot Elite Instruction Manual Page 8

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  

fixtures may be implemented in a 3-pin DMX line. When inserting stan-

dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Pin 5 - Do Not Use

Pin 4 - Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

 Inno Spot Elite    

                                           Set Up

a  male  and  female  XLR  connector  on  either  end  of  the  cable.  Also 

remember that DMX cable must be daisy chained and cannot be split.

 Inno Spot Elite    

 

                                 Set Up

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

With  this  feature  you  can  connect  the  fixtures  to  one  another 

using the IEC input and output sockets. The quantity that can be 

connected is 4 fixtures maximum for 120V and 8 fixtures maxi-

mum for 240V. After the maximum fixtures has been reached you 

will need to use a new power outlet. They must be the same fix-

tures. DO NOT mix fixtures.

 Inno Spot Elite    

              Power Cord Daisy Chain

Summary of Contents for Inno Spot Elite

Page 1: ...uct names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipment building a...

Page 2: ...n important safety information regarding the use and maintenance of this unit Please keep this manual with the unit for future reference Inno Spot Elite General Instructions Inno Spot Elite General In...

Page 3: ...uch as radiators heat registers stoves or other appliances including amplifiers that produce heat The fixture should be serviced by qualified service personnel when A Objects have fallen or liquid has...

Page 4: ...ed by the controller could be the last fixture in the chain When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is...

Page 5: ...n reduces signal errors and avoids signal transmission problems and interference It is always advisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX and PIN 3 DMX of the last f...

Page 6: ...or DOWN buttons to find your desired show and press ENTER to confirm After pressing ENTER press and hold the MENU button for at least 3 seconds to activate SHOWS Show 1 For fixtures placed on the floo...

Page 7: ...ite System Menu press ENTER Either Slave 1 or Slave 2 will be displayed 2 Press the UP or DOWN buttons until your desired slave mode is displayed press ENTER to confim NOTE In a Master Slave configura...

Page 8: ...etting press ENTER to confirm Auto Test This function will run a self test program 1 Press the MENU button until Auto Test is displayed press ENTER 2 The fixture will now run a self test Press the MEN...

Page 9: ...Home setting adjustment for the color wheel 1 Press the ENTER button for at least 3 seconds then press the UP or DOWN buttons so that Color Offset is displayed press ENTER 2 Use the UP and DOWN button...

Page 10: ...of the DMX values and traits 2 To control your fixture in DMX mode follow the set up procedures on pages 5 7 as well as the set up specifications that are includ ed with your DMX controller 3 Use the...

Page 11: ...ntrol The optional UC3 Controller not included may be used to con trol different functions including blackout Stand By Blackout the unit Function 1 Sync Strobe 2 Async strobe 3 Sound Strobe Show 1 4 1...

Page 12: ...CKWISE SLOW FAST 8 PRISM 0 7 NO EFFECT 8 255 PRISM EFFECT 9 PRISM ROTATION 0 127 COUNTER CLOCKWISE INDEX 0 360 128 189 COUNTER CLOCKWISE FAST SLOW 190 193 STOP 194 255 CLOCKWISE SLOW FAST 10 FOCUS 0 2...

Page 13: ...th glass cleaner and a soft cloth every 20 days 4 Clean the internal optics with glass cleaner and a soft cloth every 30 60 days 5 Always be sure to dry all parts completely before plugging the unit b...

Page 14: ...ects the reliability of the product if the product has been repaired or serviced by anyone other than the ADJ Products LLC factory unless prior written authorization was issued to purchaser by ADJ Pro...

Reviews: