background image

ADJ Products, LLC  -  www.adj.com  - Inno Spot Elite Instruction Manual Page 6

ADJ Products, LLC  -  www.adj.com  - Inno Spot Elite Instruction Manual Page 7

Power Supply:

 The ADJ Inno Spot Elite contains a automatic volt-

age switch, which will auto sense the voltage when it is plugged into 

a power source. With this switch there is no need to worry about the 

correct power voltage, this unit can be plugged in anywhere.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 

communication between intelligent fixtures and controllers. A  DMX 

controller sends DMX data instructions from the controller to the fix-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX Linking: 

DMX  is  a  language  allowing  all  makes  and  models 

of different manufactures to be linked together and operate from a 

single  controller,  as  long  as  all  fixtures  and  the  controller are DMX 

compliant.  To ensure proper DMX data transmission, when using 

several DMX fixtures try to use the shortest cable path possible. The 

order in which fixtures are connected in a DMX line does not influence 

the DMX addressing. For example; a fixture assigned a DMX address 

of 1 may be placed anywhere in a DMX line, at the beginning, at the 

end, or anywhere in the middle. Therefore, the first fixture controlled 

by the controller could be the last fixture in the chain. When a fixture 

is assigned a DMX address of 1, the DMX controller knows to send 

DATA assigned to address 1 to that unit, no matter where it is located 

in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 

Operation): 

The Inno Spot Elite can be controlled via DMX-512 proto-

col. The Inno Spot Elite is a 15 channel DMX unit. The DMX address 

is set electronically using the controls on the front 

panel of the unit. Your unit and your DMX control-

ler  require  a  approved  DMX-512  110  Ohm  Data 

cable for data input and data output (Figure 1). We 

recommend  Accu-Cable  DMX  cables.  If  you  are 

making your own cables, be sure to use standard 

110-120 Ohm shielded cable  (This  cable  may  be 

purchased  at  almost  all  professional  sound  and 

lighting stores). Your cables should be made with 

 Inno Spot Elite                                                        Set Up

Figure 1

 Inno Spot Elite    

                                   Installation

Screw one clamp via a M12 screw and nut onto the Omega 

holder. Insert the quick-lock fasteners of the Omega holder 

into the respective holes on the bottom of the Inno Spot Elite. 

Tighten the quick-lock fasteners fully clockwise. Pull the safety-

cable through the safety-cable slot on the bottom of the base 

and over the trussing system or a safe fixation spot. Insert the 

end in the carabine and tighten the safety screw.

NOTICE:

 The suitable enviromental temperature for this light-

ing fixture is between -25˚ C to 45˚ C. Do not place this lighting 

fixture in an enviroment where the temperatures are under or 

above the temperatures stated above. This will allow the fixture 

to run at its best and help prolong the fixture life. 

1/4 tur

n

1/4 tur

n

 tur

n

1

2

3

4

5

6

Summary of Contents for Inno Spot Elite

Page 1: ...uct names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipment building a...

Page 2: ...n important safety information regarding the use and maintenance of this unit Please keep this manual with the unit for future reference Inno Spot Elite General Instructions Inno Spot Elite General In...

Page 3: ...uch as radiators heat registers stoves or other appliances including amplifiers that produce heat The fixture should be serviced by qualified service personnel when A Objects have fallen or liquid has...

Page 4: ...ed by the controller could be the last fixture in the chain When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is...

Page 5: ...n reduces signal errors and avoids signal transmission problems and interference It is always advisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX and PIN 3 DMX of the last f...

Page 6: ...or DOWN buttons to find your desired show and press ENTER to confirm After pressing ENTER press and hold the MENU button for at least 3 seconds to activate SHOWS Show 1 For fixtures placed on the floo...

Page 7: ...ite System Menu press ENTER Either Slave 1 or Slave 2 will be displayed 2 Press the UP or DOWN buttons until your desired slave mode is displayed press ENTER to confim NOTE In a Master Slave configura...

Page 8: ...etting press ENTER to confirm Auto Test This function will run a self test program 1 Press the MENU button until Auto Test is displayed press ENTER 2 The fixture will now run a self test Press the MEN...

Page 9: ...Home setting adjustment for the color wheel 1 Press the ENTER button for at least 3 seconds then press the UP or DOWN buttons so that Color Offset is displayed press ENTER 2 Use the UP and DOWN button...

Page 10: ...of the DMX values and traits 2 To control your fixture in DMX mode follow the set up procedures on pages 5 7 as well as the set up specifications that are includ ed with your DMX controller 3 Use the...

Page 11: ...ntrol The optional UC3 Controller not included may be used to con trol different functions including blackout Stand By Blackout the unit Function 1 Sync Strobe 2 Async strobe 3 Sound Strobe Show 1 4 1...

Page 12: ...CKWISE SLOW FAST 8 PRISM 0 7 NO EFFECT 8 255 PRISM EFFECT 9 PRISM ROTATION 0 127 COUNTER CLOCKWISE INDEX 0 360 128 189 COUNTER CLOCKWISE FAST SLOW 190 193 STOP 194 255 CLOCKWISE SLOW FAST 10 FOCUS 0 2...

Page 13: ...th glass cleaner and a soft cloth every 20 days 4 Clean the internal optics with glass cleaner and a soft cloth every 30 60 days 5 Always be sure to dry all parts completely before plugging the unit b...

Page 14: ...ects the reliability of the product if the product has been repaired or serviced by anyone other than the ADJ Products LLC factory unless prior written authorization was issued to purchaser by ADJ Pro...