Power Supply:

 The ADJ Inno Pocket Spot contains a automatic volt-

age switch, which will auto sense the voltage when it is plugged into 

the power source. With this switch there is no need to worry about the 

correct power voltage, this unit can be plugged in anywhere.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 

communication between intelligent fixtures and controllers. A  DMX 

controller sends DMX data instructions from the controller to the fix-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX Linking: 

DMX  is  a  language  allowing  all  makes  and  models 

of different manufactures to be linked together and operate from a 

single  controller,  as  long  as  all  fixtures  and  the  controller are DMX 

compliant.  To ensure proper DMX data transmission, when using 

several DMX fixtures try to use the shortest cable path possible. The 

order in which fixtures are connected in a DMX line does not influence 

the DMX addressing. For example; a fixture assigned a DMX address 

of 1 may be placed anywhere in a DMX line, at the beginning, at the 

end, or anywhere in the middle. Therefore, the first fixture controlled 

by the controller could be the last fixture in the chain. When a fixture 

is assigned a DMX address of 1, the DMX controller knows to send 

DATA assigned to address 1 to that unit, no matter where it is located 

in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 

Operation): 

The Inno Pocket Spot can be controlled via DMX-512 pro-

tocol. The Inno Pocket Spot two DMX channel modes; 9 channel mode 

& 11 channel mode. The DMX address is set elec-

tronically using the controls on the front panel of 

the unit. Your unit and your DMX controller require 

a approved DMX-512 110 Ohm Data cable for data 

input and data output (Figure 1). We recommend 

Accu-Cable  DMX  cables.  If  you  are  making  your 

own cables, be sure to use standard 110-120 Ohm 

shielded  cable  (This  cable  may  be  purchased  at 

almost all professional sound and lighting stores). 

 Inno Pocket Spot                                               DMX Set Up

Figure 1

Screw one clamp via a M12 screw and nut to the included 

bracket. Attach the bracket using the included screws to the 

bottom of the Inno Pocket Spot. Attach the eyehole screw to 

the bottom of the base and pull the safety-cable through the 

screw and over the trussing system or a safe fixation spot. 

Insert the end in the carabine and tighten the safety screw.

NOTICE:

 The suitable enviromental temperature for this light-

ing fixture is between -25˚ C to 45˚ C. Do not place this lighting 

fixture in an enviroment where the temperatures are under or 

above the temperatures stated above. This will allow the fixture 

to run at its best and help prolong the fixture life. 

 Inno Pocket Spot   

                                      Mounting

Summary of Contents for INNO POCKET SPOT

Page 1: ...ct names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipment building an...

Page 2: ...rtant safety information regarding the use and maintenance of this unit Please keep this manual with the unit for future reference Inno Pocket Spot General Instructions Inno Pocket Spot General Inform...

Page 3: ...ated away from heat sources such as radiators heat registers stoves or other appliances including amplifiers that produce heat The fixture should be serviced by qualified service personnel when A Obje...

Page 4: ...in the middle Therefore the first fixture controlled by the controller could be the last fixture in the chain When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assig...

Page 5: ...tic behavior DMX512 IN 3 PIN XLR SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT DMX512 DMX DMX COMMON 1 2 3 T...

Page 6: ...isplayed press ENTER Either 9CH or 11CH will be displayed 2 Press the UP or DOWN buttons to find your desired DMX channel mode and press ENTER to confim and exit SHND Show modes 0 4 Factory programs S...

Page 7: ...n until DIND is displayed press ENTER 1 of 5 dimmer curves will be displayed STDA standard STGE stage TV TV ARAL theatrical or THAL Architec tural 2 Press the UP or DOWN buttons to find your desired d...

Page 8: ...ton until TEST is displayed press ENTER 2 The fixture will now run a self test FHRS With this function you can display the running time of the unit 1 Press the MENU button until FHRS is displayed pres...

Page 9: ...r DOWN buttons so that ON is dis played and press ENTER 2 Press the MENU button until SENS is displayed and press ENTER Use the UP and DOWN buttons to adjust the sound sensitivity Press ENTER when you...

Page 10: ...r SOUND ON OFF These buttons activate and deactivate the sound active mode SHOW This activates the show mode Use the DIMMER and DIMMER buttons to scroll through the 4 shows Inno Pocket Spot Remote Ope...

Page 11: ...70 ARCHITECTURAL 171 213 THEATER 214 255 DEFAULT TO UNIT CURVE SETTING Inno Pocket Spot 9 Channel Mode Channel Value Function 1 0 255 PAN MOVEMENT 8bit 2 0 255 TILT MOVEMENT 8bit 3 COLORS 0 7 WHITE 8...

Page 12: ...CKOUT WITH GOBO CHANGE 120 129 NO BLACKOUT WITH GOBO CHANGE 130 199 NO FUNCTION 200 209 RESET ALL 210 249 NO FUNCTION 250 255 SOUND ACTIVE MODE 11 DIMMER CURVES 0 41 STANDARD 42 84 STAGE 85 127 TV 128...

Page 13: ...and fan grill 3 Clean the external optics with glass cleaner and a soft cloth every 20 days 4 Clean the internal optics with glass cleaner and a soft cloth every 30 60 days 5 Always be sure to dry all...

Page 14: ...ner which ADJ Products LLC concludes after inspection affects the reliability of the product if the product has been repaired or serviced by anyone other than the ADJ Products LLC factory unless prior...

Reviews: