This number represents the delay setting. Use the UP and DOWN
buttons to adjust the blackout delay.
Example: If the delay is set to 3 seconds, when you are in 14
Channel mode under DMX control, and the channel 12 values are
between 226-235, the fixture will move, and then blackout after
3 seconds.
3. Press ENTER to confirm.
White Balance
- With this function you can adjust the
RGB colors to make your desired color.
1. Press the MENU button until “White Balance” is displayed,
press ENTER.
2. Use the UP or DOWN buttons to find the color you wish to
adjust.
3. Once you find the color you want to adjust press ENTER, the
displayed value will begin to flash. Use the UP or DOWN but-
tons to adjust the value. Once you have made your adjustment
press ENTER.
4. Repeat steps 2-3 until satisfied.
Manual Test
- With this function you can manually test
the individual features.
1. Press the MENU button until “Manual Test” is displayed,
press ENTER.
2. Use the UP or DOWN buttons to find the functions or colors
that you wish to test. You can test the strobe function, dimmer,
and zoom.
3. Once you find a function or color you wish to test, press the
ENTER button, the displayed value will begin to flash. You can
now adjust the values by pressing the UP and DOWN buttons.
Inno Color Beam Z7 System Menu
Inno Color Beam Z7 System Menu
Pan Inverse
- Pan Inversion
1. Press the MENU button until “Pan Inverse” is displayed,
press ENTER. Either “Yes” or “No” will be displayed.
2. To activate the Pan inversion press the UP or DOWN buttons
until “Yes” is displayed, press ENTER to confim. To deactivate
Pan inversion, select “No” and press Enter.
Tilt Inverse
- Tilt Inversion
1. Press the MENU button until “Tilt Inverse” is displayed, press
ENTER. Either “Yes” or “No” will be displayed.
2. To activate the Tilt inversion press the UP or DOWN buttons
until “Yes” is displayed, press ENTER to confim. To deactivate
Tilt inversion, select “No” and press Enter.
Back Light
- With this function you can make the back-
light automatically turn off after one minute.
1. Press the MENU button until “Back Light” is displayed, press
ENTER.
2. Either “ON” or “OFF” will now be displayed. Press the UP or
DOWN buttons to select “ON” to keep the backlight on at all
times, or “OFF” to allow the backlight to turn off after 2 minutes.
Press any button to turn the backlight on again.
3. Press ENTER to confirm.
Function Delay
- With this function the blackout func-
tion under 14 Channel mode can be delayed.
1. Press the MENU button until “Function Delay” is displayed,
press ENTER.
2. Either “No Delay” or time between 1s - 3s will be displayed.