background image

©

American DJ

®

 - www.americandj.com - Image 8 DMX™ Instruction Manual Page 17

Fixture Cleaning:

 Due to fog residue, smoke, and dust cleaning the 

internal and external lenses should be carried out periodically to opti-

mize light output.  
1.   Use normal glass cleaner and a soft cloth to wipe down the out 

  side casing.

2.   Clean the external optics with glass cleaner and a soft cloth every  

  20 days.

4.   Always be sure to dry all parts completely before plugging the   unit  

  back in.
Cleaning frequency depends on the environment in which the fixture 

operates (I.e. smoke, fog residue, dust, dew). In heavy use we recom-

mend cleaning on a monthly basis. Periodic cleaning will ensure lon-

gevity, and crisp beam output.

  Image 8 DMX™  

 

 

 

       Cleaning

This chart list the DMX dipswitch setting for DMX address 1 through 
511.  Follow  the  instructions  below  to  configure  fixture  dipswitches 
with your desired DMX address.

  Image 8 DMX™  

                     Dipswitch Chart

  Image 8 DMX™  

 

               Breaker Reset

This  unit  is  equipped  with  a  built-in  safety  breaker.  This  breaker  is 
designed to close the power circuit in the event of an internal short 
or power surge. This will reduce the risk of electrical shock or fire and 
protect the circuitry. To reset the breaker, push the breaker button in 
until you hear it “pop” back in to place. If the breaker continues to pop, 
stop using the unit and contact our customer support team, the unit 
may need to be returned for service.

©

American DJ

®

 - www.americandj.com - Image 8 DMX™ Instruction Manual Page 18

Summary of Contents for IMAGE 8 DMX

Page 1: ...o be controlled via DMX controller The unit s sound sensitivity may be adjusted by a sensitivity knob on the rear of the unit For best results use fog or special effects smoke to enhance the beams pro...

Page 2: ...ompatible 3 Channels Master Slave Operation 14 Patterns Volume Sensitivity Knob Safety Issues This unit may pop the breaker if the maximum allotted load of 2 amps is reached To reduce the risk of elec...

Page 3: ...it is not legal to aim Class 3R lasers in areas which people can get exposed This is true even if it is aimed below people s faces such as on a dance floor Do not operate the laser without first read...

Page 4: ...es a 1 4 6 3mm micro phone jack The optional blackout controller plugs in here and is used to control the first unit and other units if linked together It controls stand by and blackout function 2 Mic...

Page 5: ...h dipswitch represents a binary value Dipswitch 1 address equals 1 Dipswitch 2 address equals 2 Dipswitch 3 address equals 4 Dipswitch 4 address equals 8 Dipswitch 5 address equals 16 Dipswitch 6 addr...

Page 6: ...reduces signal errors and avoids signal transmission problems and interference It is always advisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX and PIN 3 DMX of the last fi...

Page 7: ...than a 100 feet use a terminator on the last fixture 3 Assign a DMX address to the unit by following the dipswitch chart on page 17 4 The Image 8 DMX uses three DMX channels See page 16 for detailed d...

Page 8: ...s and Patterns Laser Light CH2 00 255 Black 00 CH3 00 16 00 17 33 34 50 51 67 68 84 85 101 102 118 119 135 136 152 153 169 170 186 187 203 204 220 221 237 238 254 Picture 255 Picture1 Picture2 Picture...

Page 9: ...odic cleaning will ensure lon gevity and crisp beam output Image 8 DMX Cleaning This chart list the DMX dipswitch setting for DMX address 1 through 511 Follow the instructions below to configure fixtu...

Page 10: ...include maintenance cleaning or periodic check up During the period specified above American DJ Inc will replace defec tive parts at its expense with new or refurbished parts and will absorb all expen...