background image

  FREQ Matrix Quad                                Safety Precautions

ADJ Products, LLC  -  www.adj.com  - FREQ Matrix Quad Instruction Manual Page 4

ADJ Products, LLC  -  www.adj.com  - FREQ Matrix Quad Instruction Manual Page 3

•   Built in Microphone

•   4 DMX Channel Modes: 2 Channel Mode, 5 Channel Mode, 18   

  Channel Mode, & 64 Channel Mode

•  12 Show Modes 

•  4 Operating Modes - Sound Active, Show Mode, Manual Mode,  

  and DMX Control

•  Sound Sensitivity Adjustable

•  UC3 Remote Control Compatiable (Not Included)

•  Power Cord Daisy Chaining. See page 18.

•   To reduce the risk of electrical shock or fire, do not expose this unit  

   rain or moisture

•   Do not spill water or other liquids  into or on to your unit.

•   Do not attempt to operate this unit if the power cord has been   

   frayed or broken. Do not attempt to remove or break off the ground 

   prong from the electrical cord. This prong is used to reduce the risk  

   of electrical shock and fire in case of an internal short.

•   Disconnect from main power before making any type of connection.

•   Do not remove the cover under any conditions. There are no user  

   serviceable parts inside.

•   Never operate this unit when it’s cover is removed.

•   Never plug this unit in to a dimmer pack

•   Always be sure to mount this unit in an area that will allow proper  

   ventilation. Allow about 6” (15cm) between this device and a wall.

•   Do not attempt to operate this unit, if it becomes damaged.

•   This unit is intended for indoor use only, use of this product out`  

   doors voids all warranties.

•   During long periods of non-use, disconnect the unit’s main power.

•   Always mount this unit in safe and stable matter.

•   Power-supply cords should be routed so that they are not likely to  

   be walked on or pinched by items placed upon or against them,  

   paying particular attention to the point they exit from the unit. 

• Cleaning -The fixture should be cleaned only as recommended by  

  t he manufacturer. See page 17 for cleaning details.

•   Heat -The appliance should be situated away from heat sources  

   such as radiators, heat registers, stoves, or other appliances (inclu-

   d ing amplifiers) that produce heat.

•   The fixture should  be serviced by qualified service personnel when:

    A. The power-supply cord or the plug has been damaged.

    B. Objects have fallen, or liquid has been spilled into the appliance.

    C. The appliance has been exposed to rain or water.

    D. The appliance does not appear to operate normally or exhibits a  

        marked change in performance.

  FREQ Matrix Quad 

  

         Warranty Registration

  FREQ Matrix Quad  

 

                              Features

To optimize the performance of this product, please read these operat-

ing instructions carefully to familiarize yourself with the basic operations 

of this unit. These instructions contain important safety information 

regarding the use and maintenance of this unit. Please keep this manual 

with the unit, for future reference.

  FREQ Matrix Quad  

 

           General Instructions

The FREQ Matrix Quad carries a 3 year (1095 days) limited warranty. 

Please fill out the enclosed warranty card to validate your purchase 

and warranty.  You may also register your product online at www.

adj.com.  All returned service items whether under warranty or not, 

must be freight pre-paid and accompany a return authorization (R.A.) 

number. If the unit is under warranty you must provide a copy of your 

proof of purchase invoice. Please contact ADJ Products, LLC cus-

tomer support for a R.A. number.

The unit should be mounted using a mounting clamp (not provided), 

affixing it to the mounting bracket that is provided with the unit. 

Always ensure that the unit is firmly fixed to avoid vibration and slip-

ping while operating. Always ensure that the structure to which you 

are attaching the unit is secure and is able to support a weight of 10 

times the unit’s weight. Also, always use a safety cable that can hold 

12 times the weight of the unit when installing the fixture.

The equipment must be installed by a professional, and it must be 

installed in a place where it is out of the reach of people’s grasp.

  FREQ Matrix Quad  

                                    Installation

Summary of Contents for FREQ Matrix Quad

Page 1: ...Matrix Quad is a revolutionary 16 zone LED strobe The unit has 3 operating modes Sound Active Show Mode or DMX Control This unit can be used as a stand alone fixture or in a Master Slave configu ratio...

Page 2: ...appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances inclu ding amplifiers that produce heat The fixture should be serviced by qualified ser...

Page 3: ...t be daisy chained and cannot be split FREQ Matrix Quad Set Up Figure 1 Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug on the XLR connector Do not...

Page 4: ...at least 3 seconds CHND This will let select your desired DMX channel mode 1 Press the either the MENU button until CHND is displayed press ENTER Either 2CH 5CH 18CH or 64CH will be displayed 2 Press...

Page 5: ...gnal is lost the operating mode chosen in the setup is the running mode the fixture will go into when the DMX signal is lost You can also set this as the operat FREQ Matrix Quad System Menu ing mode y...

Page 6: ...uad has 4 DMX Modes a 2 Channel Mode 5 Channel Mode 18 Channel Mode 64 Channel Mode See pages 14 17 for a detailed description of the DMX traits 2 To control your fixture in DMX mode follow the set up...

Page 7: ...Female XLR connector is the output The first unit in the chain master will use the female XLR connector only The last unit in the chain will use the male XLR connector only For longer cable runs we s...

Page 8: ...on 9 RED 3rd Row 0 255 0 100 10 GREEN 3rd Row 0 255 0 100 11 BLUE 3rd Row 0 255 0 100 12 WHITE 3rd Row 0 255 0 100 13 RED 4th Row 0 255 0 100 14 GREEN 4th Row 0 255 0 100 15 BLUE 4th Row 0 255 0 100 1...

Page 9: ...REQ Matrix Quad Trouble Shooting FREQ Matrix Quad Fuse Replacement With this feature you can connect the fixtures to one another using the IEC input and output sockets The quantity that can be connect...

Page 10: ...LLC concludes after inspection affects the reliability of the product if the product has been repaired or serviced by anyone other than the ADJ Products LLC factory unless prior written authorization...