background image

P

ower Supply:

 The American DJ Flat Par QWH12X contains a auto-

matic voltage switch, which will auto sense the voltage when it is 

plugged into the power source. With this switch there is no need to 

worry about the correct power voltage, this unit can be plugged in 

anywhere.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To ensure proper DMX data transmission, when using several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Flat Par QA12 can be controlled via DMX-512 protocol. The Flat 

Par QA12 has 8 DMX channel modes, please see pages 9-10 for the 

different DMX modes. The DMX address is set on the back panel of the 

Flat Par QWH12X. Your unit and your DMX controller require a stan-

dard 3-pin XLR connector for data input and data 

output (Figure 1). We recommend Accu-Cable 

DMX cables. If you are making your own cables, 

be sure to use standard 110-120 Ohm shielded 

cable (This cable may be purchased at almost all 

pro lighting stores). Your cables should be made 

with a male and female XLR connector on either 

end of the cable. Also remember that DMX cable 

must be daisy chained and cannot be split.

©

American DJ

®

  -  www.Americandj.com  - Flat Par QWH12X User Manual Page 5

  Flat Par QWH12X                                                     Set Up

©

American DJ

®

  -  www.Americandj.com  - Flat Par QWH12X User Manual Page 6

Figure 1

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

  Flat Par QWH12X  

                                          Set Up

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  

fixtures may be implemented in a 3-pin DMX line. When inserting stan-

dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

Summary of Contents for Flat Par QWH12X

Page 1: ...ar QWH12X is a DMX intelligent high powered LED par fixture This fix ture can be used in a stand alone mode or connected in a Master Slave configuration This wash has five operating modes Sound Active...

Page 2: ...cular attention to the point they exit from the unit Cleaning The fixture should be cleaned only as recommended by the manufacturer See page 21 for cleaning details Heat The appliance should be situat...

Page 3: ...r Manual Page 5 Flat Par QWH12X Set Up American DJ www Americandj com Flat Par QWH12X User Manual Page 6 Figure 1 Notice Be sure to follow figures two and three when making your own cables Do not use...

Page 4: ...desired sound active program press the SET UP button to adjust the sound sensitivity When you press SET UP SJ X should be displayed Use the UP or DOWN buttons to adjust the sensitivity SJ 1 is the lea...

Page 5: ...de To run the 2 Channel Mode press the MODE button until Ch 02 is displayed This is the 2 Channel DMX Mode To run the 3 Channel Mode press the MODE button until Ch 03 is displayed This is the 3 Channe...

Page 6: ...times this indicates that you are in Color Change mode Press SPEED button and use the but tons to adjust the color change speed FLASH This button will activate the strobe effect You can control the fl...

Page 7: ...your fixture has different DMX channel modes please select your desired mode by press ing the DMX Mode button then using the or buttons to scroll through the DMX Channel Modes Set the mode before you...

Page 8: ...DMX Values Functions Channel Value Function 1 1 255 COLOR MACROS See 1 Channel DMX mode for colors 2 1 255 DIMMER 0 100 Flat Par QWH12X 3 Channel DMX Values Functions Channel Value Function 1 1 255 CO...

Page 9: ...mode for colors Flat Par QWH12X 7 Channel DMX Values Functions Channels 1 2 3 4 will not work when Channel 7 is being used Channel Value Function 1 RED 1 255 0 100 2 GREEN 1 255 0 100 3 BLUE 1 255 0...

Page 10: ...ODE 9 144 159 SOUND ACTIVE MODE 10 160 175 SOUND ACTIVE MODE 11 176 191 SOUND ACTIVE MODE 12 192 207 SOUND ACTIVE MODE 13 208 223 SOUND ACTIVE MODE 14 224 239 SOUND ACTIVE MODE 15 240 255 SOUND ACTIVE...

Page 11: ...nal in three different mounting positions hanging upside down from a ceiling hanging sideways on trussing or set on a flat level surface The unit should be mounted using a mounting clamp not provided...

Page 12: ...product if the product has been repaired or serviced by anyone other than the American DJ Inc factory unless prior written authorization was issued to purchaser by American DJ Inc if the product is d...

Reviews: