background image

©

American DJ

®

  -  www.americandj.com  - Double Feature Instruction Manual Page 6

©

American DJ

®

  -  www.americandj.com  - Double Feature Instruction Manual Page 5

Figure 1

Power Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your American DJ

®

 

Double Feature.™ The American DJ

®

 Double Feature is available in a 

120v and 220v version. Because line voltage may vary from venue to 
venue, you should be sure your unit voltages matches the wall outlet 
voltage before attempting to operate you fixture.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 
and controllers. 

A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-
els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-
minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a sin-
gle controller, as long as all fixtures and the controller are DMX com-
pliant.

 To ensure proper DMX data transmission, when using several 

DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 
may be placed anywhere in a DMX line, at the beginning, at the end, 
or anywhere in the middle. When a fixture is assigned a DMX address 
of 1, the DMX controller knows to send DATA assigned to address 1 
to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 

Operation): 

The Double Feature can be controlled via DMX-512 proto-

col. The Double Feature is a eight channel DMX unit. The DMX address 
is set on the bottom panel of the Double Feature.™ Your unit and your 
DMX controller require a standard 3-pin XLR con-
nector for data input and data output (Figure 1). If 
you are making your own cables, be sure to use 
standard two conductor shielded cable (This cable 
may  be  purchased  at  almost  all  pro  sound  and 
lighting stores). Your cables should be made with 
a male and female XLR connector on either end of 
the cable. Also remember that DMX cable must be 
daisy chained and can not be split.

 Double Feature 

 

 

 

 

     

   Set Up

 Double Feature 

 

 

 

 

     

   Set Up

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer  runs of  cable are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

Summary of Contents for Double Feature

Page 1: ...ed in multiples linked in a master slave configuration the optional BC 30 Controller may be used with in this operation for blackout program modes and program effects For best results use fog or speci...

Page 2: ...an internal short Disconnect from main power before making any type of connection Do not remove the cover under any conditions There are no user serviceable parts inside Never operate this unit when i...

Page 3: ...your DMX controller require a standard 3 pin XLR con nector for data input and data output Figure 1 If you are making your own cables be sure to use standard two conductor shielded cable This cable ma...

Page 4: ...controls gobo color wheel See page 10 for de tailed description of the DMX traits 2 To control your fixture in DMX mode follow the set up procedures on pages 5 7 as well as the set up specifications t...

Page 5: ...together using XLR cables 3 For the Master unit put dipswitch 1 in the On position and all other dipswitches in the Off position For the Slave units put any dipswitches in the On position except the...

Page 6: ...onditions Double Feature Cleaning Double Feature Trouble Shooting Fixture Cleaning Due to fog residue smoke and dust cleaning the internal and external optical lenses and mirror should be carried out...

Page 7: ...truction manual D This is not a service contract and this warranty does not include maintenance cleaning or periodic check up During the period speci ed above American DJ will replace defec tive parts...

Page 8: ...None DMX 8 Channels 4 Channels Each Side Sound Active Yes Working Position Any Safe Secure Position Warranty 1 Year 365 days Voltage is preset at the factory and is not user selectable Please Note Sp...

Reviews: