background image

Power Supply:

 The ADJ Dotz Matrix contains a automatic voltage 

switch,  which  will  auto  sense  the  voltage  when  it  is  plugged  into  a 

power source. With this switch there is no need to worry about the cor-

rect power voltage, this unit can be plugged in anywhere. Always use 

the PowerCon cord that came with the unit.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Dotz Matrix can be controlled via DMX-512 protocol. The Dotz Matrix 

has 5 DMX Channel Modes. The DMX address is set on the rear panel of 

the Dotz Matrix. Your unit and your DMX controller require a approved 

DMX-512 110 Ohm Data cable for data input and data output (Figure 

1).  We  recommend  Accu-Cable  DMX  cables.  If 

you are making your own cables, be sure to use 

standard 110-120 Ohm shielded cable (This cable 

may  be  purchased  at  almost  all  professional 

sound and lighting stores). Your cables should be 

made with a male and female XLR connector on 

either end of the cable. Also remember that DMX 

cable must be daisy chained and cannot be split.

ADJ Products, LLC  -  www.adj.com  - Dotz Matrix User Manual Page 5

  Dotz Matrix                                                               Set Up

Figure 1

  Dotz Matrix                                           Safety Precautions

ADJ Products, LLC  -  www.adj.com  - Dotz Matrix User Manual Page 4

•   To reduce the risk of electrical shock or fire, do not expose this unit  

   rain or moisture

•   Do not spill water or other liquids  into or on to your unit.

•   Be sure that the local power outlet match that of the required volt- 

   age for your unit.

•   Do not attempt to operate this unit if the power cord has been   

   frayed or broken. Do not attempt to remove or break off the ground 

   prong from the electrical cord. This prong is used to reduce the risk  

   of electrical shock and fire in case of an internal short.

•   Disconnect from main power before making any type of connection.

•   Do not remove the cover under any conditions. There are no user  

   serviceable parts inside.

•   Never operate this unit when it’s cover is removed.

•   Never plug this unit in to a dimmer pack

•   Always be sure to mount this unit in an area that will allow proper  

   ventilation. Allow about 6” (15cm) between this device and a wall.

•   Do not attempt to operate this unit, if it becomes damaged.

•   This unit is intended for indoor use only, use of this product out`  

   doors voids all warranties.

•   During long periods of non-use, disconnect the unit’s main power.

•   Always mount this unit in safe and stable matter.

•   Power-supply cords should be routed so that they are not likely to  

   be walked on or pinched by items placed upon or against them,  

   paying particular attention to the point they exit from the unit. 

• Cleaning -The fixture should be cleaned only as recommended by  

  t he manufacturer. See page 12 for cleaning details.

•   Heat -The appliance should be situated away from heat sources  

   such as radiators, heat registers, stoves, or other appliances (inclu-

   d ing amplifiers) that produce heat.

•   The fixture should  be serviced by qualified service personnel when:

    A. The power-supply cord or the plug has been damaged.

    B. Objects have fallen, or liquid has been spilled into the appliance.

    C. The appliance has been exposed to rain or water.

    D. The appliance does not appear to operate normally or exhibits a  

        marked change in performance.

Summary of Contents for DOTZ MATRIX

Page 1: ...es used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged All non ADJ Products LLC brands and product names are trademarks or regist...

Page 2: ...he carton appears to be damaged carefully inspect your fixture for any damage and be sure all accessories necessary to operate the unit has arrived intact In the case damage has been found or parts ar...

Page 3: ...emale XLR connector on either end of the cable Also remember that DMX cable must be daisy chained and cannot be split ADJ Products LLC www adj com Dotz Matrix User Manual Page 5 Dotz Matrix Set Up Fig...

Page 4: ...interference It is always advisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX and PIN 3 DMX of the last fixture 1 2 3 Figure 4 5 Pin XLR DMX Connectors Some manufactures use...

Page 5: ...he MENU button until Dim Curve is displayed press ENTER ADJ Products LLC www adj com Dotz Matrix User Manual Page 9 Dotz Matrix System Menu DMX Mode Set the DMX Address and DMX Channel Mode 1 Press th...

Page 6: ...e a terminator on the last fixture Dotz Matrix Universal DMX Control Master Slave Operation This function will allow you to link up to 16 units together and operate without a controller The units will...

Page 7: ...1 Flip 3 16 15 14 13 9 10 11 12 8 7 6 5 1 2 3 4 Flip4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 Dotz Matrix 3 Channel Mode...

Page 8: ...R FLOW 2 184 191 COLOR FLOW 3 192 199 COLOR FLOW 4 200 207 COLOR FLOW 5 208 215 COLOR FLOW 6 216 223 COLOR FLOW 7 Dotz Matrix 7 Channel Mode ADJ Products LLC www adj com Dotz Matrix User Manual Page 1...

Page 9: ...D 15 0 255 0 100 44 GREEN 15 0 255 0 100 45 BLUE 15 0 255 0 100 46 RED 16 0 255 0 100 47 GREEN 16 0 255 0 100 48 BLUE 16 0 255 0 100 Dotz Matrix 48 Channel Mode Channel Value Function 1 RED 1 0 255 0...

Page 10: ...CHANGE 168 175 COLOR FLOW 1 176 183 COLOR FLOW 2 184 191 COLOR FLOW 3 192 199 COLOR FLOW 4 200 207 COLOR FLOW 5 208 215 COLOR FLOW 6 216 223 COLOR FLOW 7 216 223 COLOR FLOW 7 224 231 COLOR FLOW 8 232...

Page 11: ...ning With this feature you can connect the fixtures to one another using the IEC input and output sockets The quantity that can be connected is 5 fixtures maximum After 5 fixtures you will need to use...

Page 12: ...erves the right to make changes in design and or improvements upon its products without any obligation to include these changes in any products theretofore manufactured No warranty whether expressed o...