Power Supply:

 

Before plugging your unit in be sure the source volt-

age in your area matches the required voltage for your American DJ

®

 

DJ Roller.™ The American DJ

®

 DJ Roller

 is available in a 120v and 

220v version. Because line voltage may vary from venue to venue, 
you should be sure your unit voltages matches the wall outlet voltage 
before attempting to operate you fi xture.  

Data Cable (DMX Cable) Requirements 
(For DMX Operation Only and Master-
Slave):

  The DJ Roller™ may be controlled via 

DMX-512 protocol. Your unit and your DMX con-
troller require a standard 3-pin XLR connector 
for data input and data output (Figure 1). If you 
are constructing your own cables, be sure to 
use standard two conductor shielded cable as 
detailed in fi gure two (This cable may be pur-
chased at almost all pro sound and lighting stores). Your cables should 
be made with a male and female XLR connector on either end of the 
cable. Also remember that DMX cable must be daisy chained and may 
not be split.

Notice:

 Be sure to follow fi gure three when making your own cables. 

Do not use the ground lug on the XLR connector. Do not connect the 
cable’s shield conductor to the ground lug or allow the shield conductor 
to come in contact with the XLR’s outer casing. Grounding the shield 
could cause a short circuit and erratic behavior.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 IN

CONNECTOR

3 PIN

DMX512 OUT

CONTROLLER

CONNECTOR

3 PIN

©

American DJ Supply

®

  -  www.americandj.com  - DJ Roller™ Instruction Manual Page 5

 

 

DJ 

Roller™ 

 

     Set 

Up

Figure 2

 

 

DJ 

Roller™ 

 

     Set 

Up

©

American DJ Supply

®

  -  www.americandj.com  - DJ Roller™ Instruction Manual Page 6

1 Ground

1 Ground

XLR Male Socket

XLR Pin Confi guration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Figure 3

Figure 1

  DJ Roller™  

 

 

 

   DMX Addressing

Special Note: Line Termination. 

When longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ part number ZDMX/T) will decrease the possibilities of erratic 
behavior. 

1

2

3

Termination reduces signal errors and
avoids signal transmission problems
and interference. It is always advisable
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.

Figure 4

DMX is short for Digital Multiplex. This is a universal binary language 
used as a form of communication between intelligent fixtures. Each 
dip switch represents a binary value.

Dip Switch 1 address equals 1 

 

Dip Switch 2 address equals 2 

 

Dip Switch 3 address equals 4 

 

Dip Switch 4 address equals 8 
Dip Switch 5 address equals 16 

 

Dip Switch 6 address equals 32
Dip Switch 7 address equals 64 

 

Dip Switch 8 address equals 128
Dip Switch 9 address equals 256

Each dip switch has a preset value, a desired DMX address is set by 
combining the dip switches that will create your desired value. For 
example: To achieve a DMX address of 21, combine dip switches 1, 3, 
and 5. Sense dip switch 1 has a value of 1, dip switch 3 has a value 
of 4, and dip switch 5 has a value of 16, the combination of the create 
a DMX value of 21.

Set DMX address 21:       

 

Set DMX address 201:

Dipswitches #  1 = 1            

 

Dipswitches #  1 = 1

 

 

3 = 4   

 

 

            4 = 8

 

 

5 = 16   

             

 

7 = 64

 

 

   = 21   

             

 

8 = 128

   

 

 

 

 

 

 

   =  201

DMX CHANNEL

1 2 3

5

4

7

9

8

6

ON

1     4    16   64  256

2     8    32  128

Summary of Contents for DJ Roller

Page 1: ...carton in the trash Please recycle when ever possible Safety Issues This unit may blow a fuse if the maximum allotted load of 15 amps is reached If the fuse needs replacement always replace the fuse w...

Page 2: ...will react to sound and chase to the several built in programs Do not spill water or other liquids into or on to your unit Be sure that the local power outlet match that of the required voltage for yo...

Page 3: ...t 2 Cold 2 Cold 3 Hot XLR Female Socket Pin 3 Data True positive Pin 2 Data Compliment negative Pin 1 Ground Figure 3 Figure 1 DJ Roller DMX Addressing Special Note Line Termination When longer runs o...

Page 4: ...t on page 13 is set up as a guide only For proper DMX addressing please refer to the DMX binary rules on page 6 DJ Roller Operating Instructions DJ Roller Operating Instructions American DJ Supply www...

Page 5: ...power before attempting to replace the lamp Lamp Replacement 1 Be sure to follow proper procedures when handling halogen lamps 2 Lamp replacement has been made simple by incorporating the use of a rem...

Page 6: ...D does not flash to sound there may be an internal problem 3 Be sure the audio sensitivity knob is turn in the full clockwise position maximum sensitivity Unit blacks out in stand alone mode 1 Some of...

Page 7: ...23 128 GOBO 10 198 219 GOBO 9 176 197 GOBO 11 220 241 SHUTTER 242 255 DJ Roller Master Slave Settings ON 8 8 8 8 8 6 9 5 4 3 7 1 2 6 9 5 4 3 7 1 2 6 9 5 4 3 7 1 2 6 9 5 4 3 7 1 2 6 9 5 4 3 7 1 2 Slave...

Page 8: ...he reli ability of the product if the product has been repaired or serviced by anyone other than the American DJ factory unless prior written authorization was issued to purchaser by Ameri can DJ if t...