Fixture Cleaning:

Due to fog residue, smoke, and dust cleaning the internal and external  

lenses should be carried out periodically to optimize light output.  
1.  Use normal glass cleaner and a soft cloth to wipe down the 

     outside casing.

2.  Clean the external optics with glass cleaner and a soft 

     cloth every 20 days.

4.  Clean the internal optics with glass cleaner and a soft cloth 

     every 30-60 days.

5.  Always be sure to dry all parts completely before plugging 

     the unit back in.
Cleaning frequency depends on the environment in which the fixture 

operates (I.e. smoke, fog residue, dust, dew). In heavy use we recom-

mend  cleaning  on  a  monthly  basis.  Periodic  cleaning  will  ensure 

longevity, and crisp beam output.

  Cross Flash™    

 

 

 

       Cleaning

  Cross Flash™   

    Fuse & Lamp Replacement

Caution:

Always  replace  with  the  exact  same  type  lamp  and  fuse, 

unless otherwise specified by an authorized American DJ

®

DJ

DJ  technician. 

®

®

Replace with anything other than the specified part can damage your 
unit and will void your manufactures warranty.

Warning: 

If  after  you  have  replaced  the  lamp  or  fuse  and  you 

continue  to  blow  either  one,  STOP  using  the  unit.  Contact  customer 
support  for  further  instructions,  you  may  have  to  return  the  unit  for 
servicing. Continuing to use the unit may cause serious damage.

Fuse Replacement:

Disconnect the unit’s main power supply. Insert a standard flat head 

screw driver in to the fuse holder housing (located on the rear of the 

unit). Turn the screwdriver in a counter-clockwise direction to remove 

the fuse holder. Remove the old fuse and discard it, replace the fuse 

with the same type. Insert the fuse holder back into it’s housing and 

turn in clockwise direction to lock the holder in place.

Lamp Replacement:

Caution!  Never  open  the  unit  when  in  use.  Always  disconnect  the 

main power and allow the fixture ample time to cool before attempting 

to  replace  the  lamp.  Lamp  replacement  has  been  made  simple  by 

incorporating  a  split  dome  that  is  retained  by  thumb  screws. 

Again, 

please remember to always replace with the exact same type lamp. 

1.   Be  sure  to  follow  the  proper  procedures  when  handling  halogen

      lamps. 

Never touch the new lamp with your bare fingers.

2.   Unscrew the single thumb screw located on the bottom of the front 

      cooling fan.

3.   Carefully lift the cooling fan housing up to expose the lamp.

4.   Remove and replace the lamp with an exact match.

5.   Reassemble in reverse order.

©

American DJ Supply

®

  -  www.americandj.com - Cross Flash™ Instruction Manual Page 6

Trouble Shooting:

Listed below are a few common problems and solutions you should try 

before contacting customer support.

Unit rotates but has no light output from the unit;

1.   Be sure you have connected your unit into a matching wall outlet.  

2.    Remove the lamp cover and be sure the lamp is seated in its 

 

 socket properly. Occasionally lamps become loose during shipping 

 

 be sure the lamp is push in to its socket all the way. 

3.   Be sure the lamp is good.

Unit does not rotate and lamp does not turn on;

1.   Be sure you have connected your unit into a matching wall outlet.  

2.    Be sure the external fuse has not blown. The fuse is located on the

   rear panel of the unit. 

3.    Be sure the unit power cord is properly seated in the power outlet 

 

 and the outlet has power.

4.   Be  sure  the  fuse  holder  is  securely  seated  in  the  fuse  holder 

 

 housing.

  Cross Flash™    

 

 

  Trouble Shooting

 Cross Flash™   

           Warranty Registration

The  Cross  Flash™  carries  a  one  year  (365  days)  limited  warranty. 

Please fill out the enclosed warranty card to validate your purchase. 

All  returned  service  items  whether  under  warranty  or  not,  must  be 

freight pre-paid and accompany a return authorization (R.A.) number. 

If the unit is under warranty you must provide a copy of your proof of 

purchase invoice. Please contact American DJ

®

 customer support for 

a R.A. number.

Summary of Contents for Cross Flash

Page 1: ... 00 p m Pacific Standard Time Voice 800 322 6337 Fax 323 582 2610 E mail support americandj com Warning To prevent or reduce the risk of electrical shock or fire do not expose this unit to rain or moisture Caution There are no user serviceable parts inside this unit Do not attempt any repairs yourself doing so will void your manufactures war ranty In the unlikely event your unit may require servic...

Page 2: ... periods of time Always be sure to mount this unit in an area that will allow proper ventilation Allow about 6 15cm between this device and a wall Never block the ventilation holes Do not attempt to operate this unit if it becomes damaged in any way Never operate this unit when it s cover is removed This unit is for adult use only Keep out of the reach of children Cross Flash Operation Power Suppl...

Page 3: ... when in use Always disconnect the main power and allow the fixture ample time to cool before attempting to replace the lamp Lamp replacement has been made simple by incorporating a split dome that is retained by thumb screws Again please remember to always replace with the exact same type lamp 1 Be sure to follow the proper procedures when handling halogen lamps Never touch the new lamp with your...

Page 4: ...f the product is modified in any manner which American DJ concludes after inspection affects the reli ability of the product if the product has been repaired or serviced by anyone other than the American DJ factory unless prior written authorization was issued to purchaser by American DJ if the product is damaged because not properly maintained as set forth in the instruction manual D This is not ...

Reviews: