background image

P

ower Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your American DJ 
46HP LED. The American DJ 46HP LED is  a 100v ~ 220v unit. Because 
of voltage setup of the unit you do not have to worry about wall output 
voltage. This unit is compatiable with all wall outputs.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 
and controllers. A DMX controller sends DMX data instructions from 
the controller to the fixture. DMX data is sent as serial data that trav-
els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-
minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 
controller,  as  long  as  all  fixtures  and  the  controller  are  DMX  compli-
ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 
DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 
may be placed anywhere in a DMX line, at the beginning, at the end, 
or anywhere in the middle. When a fixture is assigned a DMX address 
of 1, the DMX controller knows to send DATA assigned to address 1 
to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The 46HP LED can be controlled via DMX-512 protocol. The 46HP LED 
has 6 DMX modes, please see page 9 for the different modes. The DMX 
address is set on the back panel of the 46HP LED. 
Your unit and your DMX controller require a stan-
dard 3-pin XLR connector for data input and data 
output  (Figure  1).  We  recommend  Accu-Cable 
DMX cables. If you are making your own cables, 
be  sure  to  use  standard  110-120  Ohm  shielded 
cable (This cable may be purchased at almost all 
pro lighting stores). Your cables should be made 
with a male and female XLR connector on either 
end of the cable. Also remember that DMX cable 
must be daisy chained and cannot be split.

©

American DJ

®

  -  www.Americandj.com  - 46HP LED User Manual Page 5

  46HP LED                                                                  Set Up

©

American DJ

®

  -  www.Americandj.com  - 46HP LED User Manual Page 6

Figure 1

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

 46HP LED   

                                                     Set Up

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  
fixtures may be implemented in a 3-pin DMX line. When inserting stan-
dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 
these adaptors are readily available at most electric stores. The chart 
below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

Summary of Contents for 46HP LED

Page 1: ...re can be used in a stand alone mode or connected in a Master Slave configuration The unit can also be controlled via DMX controller This wash has four operating modes Sound Active mode Auto mode RGB...

Page 2: ...rticular attention to the point they exit from the unit Cleaning The fixture should be cleaned only as recommended by the manufacturer See page 15 for cleaning details Heat The appliance should be sit...

Page 3: ...com 46HP LED User Manual Page 5 46HP LED Set Up American DJ www Americandj com 46HP LED User Manual Page 6 Figure 1 Notice Be sure to follow figures two and three when making your own cables Do not u...

Page 4: ...male XLR connector is the ouput The first unit in the chain master will use the female XLR connector only The last unit in the chain will use the male XLR connector only 2 Set the Master unit to your...

Page 5: ...Mode press the MODE button until 3000 is displayed This is the DMX addressing for the 3 Channel Mode 6 To run the 4 Channel Mode press the MODE button until 4000 is displayed This is the DMX addressin...

Page 6: ...ROBING 0 15 NOTHING 16 255 STROBING SLOW FAST 6 MASTER DIMMER 1 255 0 100 46HP LED 6 Channel DMX Values Functions 46HP LED 2 Channel DMX Values Functions Channel Value Function 1 1 255 COLOR MACROS Se...

Page 7: ...255 0 100 46HP LED 7 Channel DMX Values Functions Channel 1 2 and 3 will not work when Channel 4 is being used When using Channel 6 Channel 5 will control the speed of the color changing 46HP LED Back...

Page 8: ...described above Except to the extent prohibited by applicable law all implied warranties made by American DJ Inc in connection with this product including warranties of merchantability or fitness are...

Page 9: ...46HP LED Notes 46HP LED Notes American DJ www Americandj com 46HP LED User Manual Page 18 American DJ www Americandj com 46HP LED User Manual Page 17...

Page 10: ...Channel Mode 7 Channel Mode Warranty 3 Year 1 095 days Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice Am...

Reviews: