AK INSTALLATION AND SERVICE INSTRUCTIONS
4211-1551 06/18/18 Technical Support: 1-425-951-1120 1-800-363-0251 [email protected] Page
16
of
20
SECTION 5. BATH CONTROLS INSTALLATION (continued)
Locate the control cable, pull it out through the mounting hole and plug it into
the connector on the back of the control board,, inside the housing.
Run a bead of 100% silicone caulk around the perimeter on the back of the
control housing. See Diagram 12. Insert the control into the wall cavity. See
Diagram 13.
Connect the R30K control's cable to the steamer and plug it in to the S30B
jack (top edge of the circuit board next to the S30A terminal block).
DIAGRAM 13
3C. INSTALL GENERATOR CONTROL (R30i):
The R30i low voltage control can be mounted directly to a finished wall either inside or outside the steam room.
T
he R30i does not control the temperature in the steam room.
Use a 1-1/2” (36 mm) hole saw to drill a hole in the finished steam room wall where the control is to be mounted
(the control cable should already be roughed-in to this location). See Diagram 13.
Locate the control cable, pull it out through the hole and connect the cable wires to the terminal block on the back
of the R30i circuit board inside the housing.
The cable wires must be connected to the same terminal position
numbers at the control and at the steamer!
For example, connect the cable’s black wire to position 1 at both
ends, red to position 2 at both ends and white to position 3 at both ends.
Run a bead of 100% silicone caulk around the perimeter on the back of the control housing. Insert the control into
the wall cavity. See Diagram 13.
Connect the R30i control's cable wires to the steamer's circuit board terminal block. See Diagram 13.
DIAGRAM 12
SILICONE
R30K
1-1/2” (36 mm)
HOLE
R30i
1-1/2” (36 mm)
HOLE