11

*

Connection of power cable

*

INSTALLATION & REPAIR GUIDE

Split Wall-Mounted air conditioner

1.Remove the drawer of the outdoor unit.

2.Connect the indoor power and control 

wires with the matched outdoor wires in accordance 

with the electric schematic diagram and make sure

that the connection is firmly done(Fig.7)

wire pressing plate

Drawer screw

3.Use a press plate to fix the wires firmly,and re-install 

the drawer.

Note:Do not connect the wires in a wrong  way,otherwise electric malfunctions will be caused and 

even damages to the units will occur.The appliance shall be installed in accordance with national 

wiring regulation.If the supply cord is damaged,it must be replaced by the manufacturer or its service 

agent or a similarly qualified person in order to avoid a hazard.The plug shall be accessible after 

installing the appliance.If the model have not plug that a switch which have a contact separation 

of at least 3 mm(1/10") in all poles shalled be added in fixed wiring.

Use thermal tube to wrap the joints and wrap the tube tightly with ethylene tapes.

Fix the wrapped pipelines on the exterior wall with clamps.

Fill in the gaps left over by the pipeline hole and wall hole to prevent rain-water from entering.

*

Finishing touches 

*

Connect to the power source,check if the function selection keys on the remote controller are 

       working properly.

Check if the room temperature  adjustments and timer settings are working properly.

Check if the drain is smooth.

Check if there is any abnormal noise or vibration during operation.

Check if there is leakage of refrigerant.

*

Test running

*

Fig.

7

*

Is the unit installed correctly? 

*

*

Isn't there anything which prevents ventilation or obstructs operation in front of the indoor unit ? 

Do not install the unit following place .

*

Inflammable gases may leak .  

*

Oil splashes a lot .

*

In case where the unit is used in such places as poisonous or sultry gases are generated or seaside 

district exposed to sea breezes corrosion  may cause malfunction . Consult with your distributor . 

*

Air conditioner body and remote controller must be I m(39-3/4") or more away from a TV or a radio. 

Drain the dehumidified water from the indoor unit to a place which drains well .

*

When installing the unit , choose a place which can stand the weight of the unit well and does 

not increase the operation noise or vibration . Especially where there is a possibility that vibration 

be transmitted to the house , fix the unit by inserting attached vibration -proof pads between the 

unit and fittings .

*

Suitable Installation Position

*

Pay attention to operation noise

Summary of Contents for UCHW-H09AF2

Page 1: ......

Page 2: ......

Page 3: ...he unit during operation the fire alarm device might be erroneously triggered by the warm air from the unit Above 100mm 4 Left side 150mm 6 and above Right side 150mm 6 and above Ceiling Wall hanging...

Page 4: ...ions To avoid the air outlet being directly against the wind Detailed space requirements around the outdoor unit 1 When there are obstacles above the unit 2 When the front air outlet is open 3 When th...

Page 5: ...rfaces if the humidity is very high 4 Installation of indoor unit Pass the connection wires connecting pipelines and drain pipe through the wall hole Hang the indoor unit on the hooks at the top of th...

Page 6: ...ity center of the unit is not at the installation center special caution should be taken when using hoisting cables to lift it up During shipping the outdoor unit must not be slanted to over 45 degree...

Page 7: ...9 000 BTU 12 000 BTU MODEL 9 000 BTU 12 000 BTU MODEL 18 000 BTU 24 000 BTU MODEL...

Page 8: ...INSTALLATION REPAIR GUIDE Split Wall Mounted air conditioner...

Page 9: ...is suitable for non quick coupler No dust foreign articles air or moisture should be allowed to enter the air conditioning system Careful attention should be paid when pipeline connection for outdoor...

Page 10: ...Air Purging Air purging With Vacuum Pump 8...

Page 11: ......

Page 12: ...10...

Page 13: ...wall hole to prevent rain water from entering Finishing touches Connect to the power source check if the function selection keys on the remote controller are working properly Check if the room tempera...

Page 14: ...on or increased operation noise Do not leave obstacles near the outlet and inlet If irregular sound is heard during operation consult with your distributor Inspection and Maintenance Note Above self c...

Page 15: ......

Page 16: ......

Reviews: