Problem

Cause

Solution

The unit does 
not function

Check the plug fuse. Check 
the  mains outlet by connecting 
another appliance

Connect to a functioning outlet and 
switch on

Water container indicator is on

Empty water container

Room temperature outside 
operating temperature range

The unit does 
not seem to 
perform

In direct sunlight

Close curtains

Windows or doors open, many 
people or heat source in room
Dirty filter

Clean or replace filter

Air inlet or air outlet blocked

Remove blockage

Room temperature lower than 
selected value

Change temperature selection

The unit is noisy

Unit stands uneven

Place on even surface (less vibrations)

The compressor 
does not work

Overheat protection probably 
activated

Wait until room temperature lowers

  

TROUBLE 

SHOOTING

Model

AMC 

7KM-410

AMC 

10KM-410

AMC 

12KM-410

Cooling capacity

measured conform EN 14511

BTU/h

6500

8300

9600

kW

1.9

2.4

2.8

Mains

220–240 V / 50 Hz / 1 phase

Power consumption

W

690

830

1030

Current

A

3.0

3.7

4.5

Dehumidification

L/24h

24

28.8

36

Air delivery

m

3

/h

300

350

350

Recommended room size

m

2

12

18

24

Refrigerant

type

R410A

Compressor

rotary

Fan speeds

2

Thermostat

°C

18 – 32

Timer

h

1 – 8

Dimensions (W x H x D)

mm

377 x 750 x 400

Weight

kg

29

30

32

Subject to modifications without prior notice. Please refer to the rating label for greater precision.

  

TECHNICAL 

DATA

Summary of Contents for AMC 10KM-410

Page 1: ...PORTABLE AIR CONDITIONER GB Portable air conditioner AMC 7KM 410 10KM 410 12KM 410...

Page 2: ...S 15 14 11 12 10 13 16 17 5 8 7 9 6 4 1 2 3 5 Air filter 6 Air inlet 7 Exhaust air outlet 8 Cord hanger 9 Water stopper plug inside 10 Foam extension 11 Foam with hole 12 Water tray 13 Hose adapter 14...

Page 3: ...f the country where the unit is used If you are in any doubt about the electrical installation have it checked and if necessary modified by a qualified electrician The air conditioner is safe However...

Page 4: ...ating is 230 volts and should be protected by a 13 amp fuse either in the plug or distribution board The appliance is supplied with a moulded 13 amp 3 pin mains plug fitted with a 13 amp fuse Should t...

Page 5: ...n the warm air from re entering the room fig 5 Depending on how the window opens horizontally fig 3a or vertically fig 3b Pass the hose through the opening in the foam 11 Permanent hole in glass or wa...

Page 6: ...ng cooling Thermostat setting Turn control 3 to maintain the temperature level in combination with cooling Notices The compressor has been set so that it starts functioning three minutes after the re...

Page 7: ...nob plug the unit in and switch on The LED 4 should now be out Rubber plug Water tray Drain control EMPTYING THE INTERNAL WATER CONTAINER Switch off the unit and remove the plug from the mains Remove...

Page 8: ...ssive chemicals petrol detergents or other cleansing solutions Filter The single layer screen filter cleans the circulated air The filter needs to be cleaned regularly with a vacuum cleaner to avoid b...

Page 9: ...om temperature lower than selected value Change temperature selection The unit is noisy Unit stands uneven Place on even surface less vibrations The compressor does not work Overheat protection probab...

Page 10: ...es 5 7 working days If the customer returns to store and claims the unit to be faulty we would ask that you carry out the same procedure as above particularly with air conditioners rather than simply...

Page 11: ...uch as filters The guarantee after repair or replacement will not be extended beyond the original one year period All replacement parts or units will be new or reconditioned Parts or units which are r...

Page 12: ...Great West Road Brentford Middlesex TW8 9ER United Kingdom Tel 44 20 8560 4141 Fax 44 20 8232 8814 Email amcoruk amcorgroup com USA Amcor Inc 685A Gotham Parkway Carlstadt New Yersey 07072 United Stat...

Reviews: