Amcor AMC 10KM-410 Instruction Manual Download Page 6

6

ON/OFF and timer function

Turn the control [1] to switch the unit on or off.  When the unit is on, LED-1 is on.

Timer function

Use control [1] to set a working time between 1 and 8 hours. The unit switches off 
when the set time has run down.

Mode selection and speed setting

Select with control [2] the required operating mode cooling or fan mode. The 
corresponding LED (2 or 3) will lit.
Select the larger symbol position for high or low fan speed, or low or strong cooling.

Thermostat setting

Turn control [3] to maintain the temperature level in combination with cooling.

Notices:

 •  The compressor has been set so that it starts functioning three minutes after the 

(re)start of the air conditioner.

 •  The cooling will switch off when the room temperature is lower than the set 

one. Ventilation will however continue to work on the set level. When the room 
temperature rises above the selected value, the cooling will work again.

Air flow

Turn the roller to control the air flow direction of the vertical 
louvres.
Move the air vent directly to adjust the air flow direction of the 
horizontal louvres.

 OPERATION

GB

3

2

1

1

2

3

4

Summary of Contents for AMC 10KM-410

Page 1: ...PORTABLE AIR CONDITIONER GB Portable air conditioner AMC 7KM 410 10KM 410 12KM 410...

Page 2: ...S 15 14 11 12 10 13 16 17 5 8 7 9 6 4 1 2 3 5 Air filter 6 Air inlet 7 Exhaust air outlet 8 Cord hanger 9 Water stopper plug inside 10 Foam extension 11 Foam with hole 12 Water tray 13 Hose adapter 14...

Page 3: ...f the country where the unit is used If you are in any doubt about the electrical installation have it checked and if necessary modified by a qualified electrician The air conditioner is safe However...

Page 4: ...ating is 230 volts and should be protected by a 13 amp fuse either in the plug or distribution board The appliance is supplied with a moulded 13 amp 3 pin mains plug fitted with a 13 amp fuse Should t...

Page 5: ...n the warm air from re entering the room fig 5 Depending on how the window opens horizontally fig 3a or vertically fig 3b Pass the hose through the opening in the foam 11 Permanent hole in glass or wa...

Page 6: ...ng cooling Thermostat setting Turn control 3 to maintain the temperature level in combination with cooling Notices The compressor has been set so that it starts functioning three minutes after the re...

Page 7: ...nob plug the unit in and switch on The LED 4 should now be out Rubber plug Water tray Drain control EMPTYING THE INTERNAL WATER CONTAINER Switch off the unit and remove the plug from the mains Remove...

Page 8: ...ssive chemicals petrol detergents or other cleansing solutions Filter The single layer screen filter cleans the circulated air The filter needs to be cleaned regularly with a vacuum cleaner to avoid b...

Page 9: ...om temperature lower than selected value Change temperature selection The unit is noisy Unit stands uneven Place on even surface less vibrations The compressor does not work Overheat protection probab...

Page 10: ...es 5 7 working days If the customer returns to store and claims the unit to be faulty we would ask that you carry out the same procedure as above particularly with air conditioners rather than simply...

Page 11: ...uch as filters The guarantee after repair or replacement will not be extended beyond the original one year period All replacement parts or units will be new or reconditioned Parts or units which are r...

Page 12: ...Great West Road Brentford Middlesex TW8 9ER United Kingdom Tel 44 20 8560 4141 Fax 44 20 8232 8814 Email amcoruk amcorgroup com USA Amcor Inc 685A Gotham Parkway Carlstadt New Yersey 07072 United Stat...

Reviews: