background image

5

Setting Mode/Function

Press the MODE button to select the required working mode: Automatic, Cooling, Fan or Heating (Heating is only
available for AL-10,000EH). The green indicator illustrating your selected mode lights up.  It is recommended to select
Cooling or Heating mode and set your desired temperature, as the Auto mode has a preset temperature (please see
below) that cannot be changed.

The indicators of the functions in progress come on at the same time, e.g. Cool and Lo = Cooling mode with Low fan speed.

Auto Mode

When this mode is selected, the unit is preset to the following temperature settings and unit will only start to:
• Cool when room temperature is higher than 75ºF
• Heat when room temperature is lower than 68ºF (AL-10,000EH only)

If room temperature is between 68ºF and 75ºF, unit will stay in Fan mode.  Again, when in Auto Mode, the temperature
settings cannot be changed.

Setting the Temperature in Cooling or Heating Mode

T

he display window’s default is to display the ambient room temperature.  The green indicator light under RT is on.

(RT = Room Temperature)

To set your desired temperature, press the Temperature up or down buttons (ranging from 62ºF to 90ºF).  Each press
will increase or decrease your set temperature by 1ºF.  When pressing the temperature up or down buttons, the
window will change to display your set temperature. At this time, the green indicator will light under ST (Set
Temperature).  Once the temperature up or down buttons is released, the window will return to displaying the
ambient temperature after a second.

Note:

  When unit is in the following modes:   Auto, Cool, or Heat - the compressor will cool/heat the room to reach

the set temperature.  Once the ambient temperature has reached the set temperature, the compressor will stop and
unit will run in Fan mode.  To conserve energy, the compressor will not start immediately after a couple degrees
increase or decrease, but will wait for a 5ºF allowance.  For example:

In Cooling Mode with a set temperature of 70ºF

When compressor first stops after reaching 70ºF, unit will auto-switch to Fan.
Compressor will start cooling again when ambient temperature increases to 75ºF or above.

In Heating Mode with a set temperature of 72ºF

When compressor first stops after reaching 72ºF, unit will auto-switch to Fan.
Compressor will start heating again when ambient temperature drops to 67ºF or below.

In Auto Mode (with preset temperature of 68ºF for heat and 75ºF for cool)

Compressor will start cooling again when ambient temperature reaches above 80ºF or will start heating when
ambient temperature drops below 63ºF.

Parts

10

11

12

13

14

15

8

4

Operation

1. Control Panel

2. Cooling Air Outlet

3. Handle

4. Castors

5. Air Filter

6. Air Inlet

7.  Exhaust Air Outlet

8. Cord Hanger

9.  Water Stopper (Rubber Plug Inside)

Accessories

10. Adaptor - for insertion over the 

hose and into the back of the
air conditioner

11. Exhaust Hose

12.  Adjustable Slide Bar

13. Round Connector

14.  Cap for Round Connector

15. Remote Control

(Electronic control models only)

Front

Back

Heating Mode Indicator

(For Models With Heating Options)

Timer Selector

Set Temperature  Indicator

Room Temperature  Indicator

Low Fan Speed Indicator

High Fan Speed Indicator

Automatic Mode Indicator

Cooling Mode Indicator

Fan Mode Indicator

Timer Operation Indicator

Temperature Up Selector

Compressor Indicator

Temperature Down Selector

Fan Speed Selector Mode (Function)

Option Selector

On/Off (Power) Selector

3

1

2

Summary of Contents for 000E AL-10

Page 1: ...which it was not designed or 4 repaired or altered in any way that adversely affected its performance or reliability To obtain warranty service the defective product or part must be shipped or deliver...

Page 2: ...and windows are open The filter is dirty Clean or replace filter Air inlet or air Remove blockage outlet is blocked Room temperature lower Lower temperature selected than the selected value The overhe...

Page 3: ...ool the unit and make it run more efficiently This is a feature not found in most Portable Air Conditioners If the unit is operated inVERY HUMID air water will collect in the container inside the unit...

Page 4: ...will cool heat the room to reach the set temperature Once the ambient temperature has reached the set temperature the compressor will stop and unit will run in Fan mode To conserve energy the compress...

Page 5: ...2 Attach Slide Bar Connector Round Connector to the other end of the Hose by extending hose at least 6 Then tighten Hose by turning the Round Connector clockwise 3 Place Adjustable Slide Bar in the wi...

Page 6: ...the one set the fan keeps working at the set level When the room temperature drops 5 F below the chosen temperature heating will resume This machine is equipped with an ANTI FROST function Sometimes w...

Page 7: ...ngThe Power Cord When the unit is not in use please store the power cord away as shown Thank You Thank you for choosing the portable air conditioner from AMCOR a leading brand in indoor air treatment...

Page 8: ...13...

Reviews: