USER
MANUAL
925NG
T
ECHNICAL
S
HEET
D.32
7844058-00 03/20
subject to change without notice
D.11
CENTERS OF GRAVITY AND TEST LOADS
This annex contains the data needed for the stability test in accordance with EN 12999.
Loads and centers of gravity
X
Z
Y
P
G
F
G
P
X
X
X
X
Pin
Pout
Gin
Gout
in
out
Hooking point for the test load
TL2
TL
TL
TL2
Key:
F = weight of fixed parts (stabilizers, base, column, 1st boom cylinder)
G = weight of booms
X
G
= distance between G and column axis
P = rated capacity
X
P
= distance between P and column axis
TL = test load, to be hooked to the last hydraulic extension
TL2 - #S = additional test load, to be hooked to the hydraulic extension indicated in the table below
X, Y, Z = coordinates of center of gravity for whole crane folded in transport position (EX-H version)
in = configuration with all hydraulic extensions fully retracted
out = configuration with all hydraulic extensions fully extracted
WEIGHTS AND CENTERS OF GRAVITY
925NG
F
kg
G
kg
X
G
in / out
m
P
in / out
kg
X
P
in / out
m
TL
(TL2 - #S)
kg
X
Y
mm
Z
2S
ST-M : 1510
EX-H : 1580
SE-H : 1735
1090
2.05
2.89
5435
2910
4.28
8.08
3638
232 755
17
3S
1230
2.17
3.51
5340
2255
4.28
10.11
2819
230 770
37
4S
1370
2.28
4.30
5045
1725
4.36
12.22
2166
221 785
55
5S
1495
2.38
5.09
4765
1320
4.44
14.43
1689
211 800
68
6S
1600
2.46
5.88
4585
1035
4.53
16.65
1355
203 812
77
7S
1720
2.52
6.63
4415
805
4.61
18.90
1006
(122 - 4S) 193 830
90
8S
1810
2.58
7.29
4280
630
4.70
21.18
788
(157 - 4S) 188 843
97
4SJ3
2030
9.13
9.39
730
515
15.21
20.41
644
(269 - 4S) 183 1007 114
5SJ3
1985
9.38
9.56
600
465
17.26
21.94
581
(228 - 5S) 194 1023 111
6SJ2
1875
9.13
9.17
570
490
19.38
22.24
613
(174 - 6S) 182 945 105
The data are relating to crane configuration with horizontal booms.
For the jib version, the "in" data are relating to standard crane's extensions always fully extracted.