Configuring Units
50
3ware 9000 Series Serial ATA RAID Controller Installation Guide
To start initialization through Verify in 3BM
1
Reboot and restart 3BM.
2
Select the array you want to verify. (Highlight it and press
Enter
.)
3
Tab
to
Maintain Array
and press
Enter
.
4
On the Maintain Disk Array screen,
Tab
to
Verify Array
and
change the selection to
Yes
.
5
Tab
to
OK
and press
Enter
.
Initialization of the unit begins.
Initialization of a RAID 1 unit results in data from one disk (the
disk on the lower channel number) being copied to the other disk.
In RAID 10 units, data from one half of the array is copied to the
other half.
After the initial verification, subsequent verifies to a RAID 1 or 10
unit check for data consistency by comparing the data from one
drive (or set of drives) to the other drive (or set of drives).
Checking the Motherboard Boot
Sequence
Using your computer’s Setup utility, ensure that it shows the
appropriate boot device.
After installing the 3ware 9000 controller in your system, go into
the BIOS for your computer system to check and change the boot
order. This is necessary because most systems automatically change
the boot order when they detect a newly installed controller and
device. Refer to the documentation for your system for information
about starting the system BIOS.
Summary of Contents for 3WARE 720-0138-00
Page 6: ...iv 3ware 9000 Series Serial ATA RAID Controller Installation Guide...
Page 8: ...About this Guide vi 3ware 9000 Series Serial ATA RAID Controller Installation Guide...
Page 34: ...Installing the Hardware 26 3ware 9000 Series Serial ATA RAID Controller Installation Guide...
Page 60: ...Configuring Units 52 3ware 9000 Series Serial ATA RAID Controller Installation Guide...