6
Scheme 4a The example of triggering the signaling device and optical indication when the system is armed/
disarmed.
„+” shorted to ground with „S” → no
alarm
(no optical-acoustic indication)
„+” opened from ground with „S” →
alarm
(optical-acoustic indication)
ARM/DISARM
LIGHT
function
(DIP4)
Arming – indicated with three short
optical flashes
Disarming – 1 longer optical signal
Scheme 4b Example of triggering the signaling device with separation of optical and acoustic signals
„+”shorted to ground with „S”
→ no alarm
(no acoustic indication)
„+”opened from ground with „S”
→ alarm (acoustic indication)
„+”shorted to ground with „A” →
no alarm (no optical indication)
„+”opened from ground with „A”
→ alarm
(optical indication)
Caution: When separating the optical and acoustic indication
(because of the use of the "A" terminal), some functions
adjustable via the switches are not available.
Scheme 4c Connection of the signaling device with two wires
Connecting the signaling device
using two power cables and the
activation
of
optical-acoustic
indication by supplying power.
Caution!
The first powering activates the
device.
The
activation
is
performed only once.
Each subsequent powering
triggers optical-acoustic
indication.