2. Installation  

 

The  signaling  device  should  be  mounted  by  a  qualified  installer,  holding  relevant  permits  and  licenses 

(applicable and required for a given country) for Intrusion Detection Systems. 

The  mounting  location  of  the  signaling  device  should  be  inaccessible  in  order  to  minimize  the  risk  of 

tampering. The signaling device should be mounted on a flat surface using expansion bolts. 

In order to open the enclosure of the SR136, unscrew the screw in the bottom of the housing and  bend 

the upper part of the enclosure (lid) upwards. 

Caution!  When  mounting,  keep  an  appropriate  distance  (minimum  5  cm)  between  the  top  edge  of  the 

enclosure of the signaling device and the ceiling or other structures located above, so that re-mounting of the 
enclosure after installation and configuration of the device will be possible. 

The view of the signaling device is shown in the pictures below. 
 

 

Fig. 1a  

The signaling device after removing the plastic housing 

 

Fig. 1b 

The signaling device after removing the plastic housing and metal enclosure 

 

 

 

 

 

 

 

 

Summary of Contents for SR136

Page 1: ...coustic indication is based on a dynamic transducer The sound intensity generated by signaling device is 120 dB at 1 meter distance Optical indication uses modern super bright LED so that the light of...

Page 2: ...losure of the SR136 unscrew the screw in the bottom of the housing and bend the upper part of the enclosure lid upwards Caution When mounting keep an appropriate distance minimum 5 cm between the top...

Page 3: ...device Power supply of the signaling device is supplied to the and terminals The signaling device can operate with or without the 12V 2 2Ah battery The battery should be connected to the BAT socket Ca...

Page 4: ...ng the A control input input polarization ON Activating the function by giving a plus to the A terminal OFF Simultaneous launching of the speaker and lamp the S terminal DIP3 CMD Separation of optical...

Page 5: ...several optical signals at the moment of disarmament DIP2 MEMORY LIGHT Optical alarm memory OFF Disabling the function ON Arming indicated by the signaling device with 3 short acoustic signals Disarm...

Page 6: ...no alarm no acoustic indication opened from ground with S alarm acoustic indication shorted to ground with A no alarm no optical indication opened from ground with A alarm optical indication Caution...

Page 7: ...ontrolling the OUT5 output shorting the output to ground which is connected via the 1k resistor it is possible to force the S input to a low state which results in activation of the signaling device 4...

Page 8: ...to periodically test the signaling device The majority of Intrusion Detection Systems indicates malfunctioning of the signaling devices and informs the user with an appropriate message on the LCD keyp...

Page 9: ...ience however not later that within 14 days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilitie...