background image

 

 
 
 

 

 

 8 

 

AV ACQUISITION 4001 / ©AMC VIBRO Sp. z o.o. 

 

7.

 

InstaCal 

To  install  the  InstaCal  utility  software  run  the  Icalsetup.exe  file 
located in the /InstaCal/ folder on the supplied CD. The software 
will request permission to unpack and to install. Click OK and Setup 
in a sequence of windows  that will appear to access  the installer 
window.  Then  click  the  Next  button  twice  (without  changing  the 
access path) to confirm that you wish to launch installation and then 
click Install

When installation is complete, click the Finish button to close the 
installer window. Restart the computer to apply the changes. 

After the restart run the InstaCal software (Start > All programs > Measurement Computing > Instacal
when the AVA module is connected to the computer. A window will appear with a list of measurement 
cards which have been detected. Mark the item named USB-1608FS, click OK and close InstaCal. 

The above procedure should be carried out once before using the data acquisition module for the 
first time in data acquisition software. 

8.

 

DASYLab® 16 configuration 

Before starting to work with the AVA module in DASYLab®, it 
need to be configured properly in the Configurator (by default: 
Start > All programs > DASYLab > Configurator). In the program’s 
window, in the Packages tab, the Measurement Computing option 
should be marked. If it is not marked, please mark it, and click the 
Enable button to launch the installation of drivers in DASYLab®. 
In a sequence of windows that will appear, click NextNextInstall 
and Finish respectively. 

The  above  procedure  should  be  carried  out  only  once  when 
using the module for the first time.  

 

Summary of Contents for AV ACQUISITION 4001

Page 1: ...MC VIBRO Sp z amc VIBRO Sp z o o ul Pilotow 2e 31 462 Krakow Poland T 48 12 362 97 60 S 48 12 362 97 63 info amcvibro pl KRS No 0000618618 REGON No 364497010 VAT No PL6772403385 www amcvibro pl 4 CHAN...

Page 2: ...3 3 Technical data 4 4 Measurement accuracy 5 5 Description of connections and status lights 7 6 Connection with a computer using Windows 7 7 7 InstaCal 8 8 DASYLab 16 configuration 8 9 Using the AVA...

Page 3: ...to 100 kS s The provided drivers allow operation with DASYLab LabVIEWTM and Matlab Module characteristics operation with four IEPE standard vibration sensors sensor circuit functional check warnings...

Page 4: ...channels is max 400 kS s Measurement range 10V 5V 2V i 1V selected by software Crosstalk 80 dB within 0 25 kHz band Maximum absolute error range 10V 5 66 mV range 5V 2 98 mV range 2V 1 31 mV Range 1V...

Page 5: ...bly small and may be overlooked The device is equipped with a 16 bit ADC converter which transforms analog signals into values ranging from 0 to 65525 The following is an ideal characteristic for a 10...

Page 6: ...elated to the difference between the slope of the real characteristics and the ideal characteristics and is expressed as a percentage For the 10 V range the gain error is 0 04 Adding the offset and th...

Page 7: ...es not require the installation of any drivers in the operating system The operating system detects a new device automatically when connected and displays it in the hardware manager as a USB HID inter...

Page 8: ...AVA module is connected to the computer A window will appear with a list of measurement cards which have been detected Mark the item named USB 1608FS click OK and close InstaCal The above procedure sh...

Page 9: ...w This window needs to be discussed in detail as it gives the user the option to configure the AVA module parameters for operation in DASYLab The following areas can be distinguished 1 You can enter y...

Page 10: ...this window in the Scan rate field it is possible enter required sampling frequency select the proper unit and in the Block size field it is possible to select proper size of data buffer Attention The...

Page 11: ...lds as required The numbers should be equal in the absolute value When different values are entered for example 1V and 2V the program will signal an error and will suggest that the greater of them for...

Reviews: