2.2.7.2  Inner Reflectors

 

2.2.7.2.1  Two Module units 

 
1. Place inner reflectors (H) on the heater by    
sliding the reflectors between the tubes and the 
brackets. 
 
2. Locate the FIRST slot on reflector over the 
M8 bolt on the first bracket. Secure using large 
washers and anti vibration nuts. 
 
3. The slot in other end of the first reflector 
should align with M8 bolt on the second bracket. 
 
4. Locate the second reflector onto the same 
bolt using the SECOND slot in from the end and 
OVERLAP the first reflector. This should create 
a 114mm overlap. Secure using large washers 
and anti vibration nuts. 

4. Locate the M8 bolts on last bracket to slot in 
second reflector approx one third distance from 
reflector end. Secure using large washers and 
anti vibration nuts. 
 
5. Slight re-adjustment of brackets may be   
necessary for reflector alignment. Ensure U 
bolts are tightened correctly as described in  
section 2.2.3. 
 
 

2.2.7.2.2  Three Module Units

 

 
1. Place inner reflectors (H) on the heater by    
sliding the reflectors between the tubes and the 
brackets. 
 
2. Locate the FIRST slot on reflector over the 

All reflectors must be positioned/
attached to the brackets exactly as 

 

 

 

detailed in the assembly drawings. 
 
Remove the protective plastic coating.

 

M8 bolt on the first bracket. Secure using large 
washers and anti vibration nuts. 
 
3. The slot in other end of the first reflector 
should align with M8 bolt on the second bracket. 
 
4. Locate the second reflector onto the same 
bolt using the FIRST slot in from the end and  
OVERLAP the first reflector. This should create 
a 77mm overlap. Secure using large washers 
and anti vibration nuts. 
 
5. The slot in other end of the second reflector 
should align with M8 bolt on the third bracket. 
 
6. Locate the third reflector onto the same bolt  
using the FIRST slot in from the end and  
OVERLAP the second reflector. This should  
create a 67mm overlap. Secure using large 
washers and anti vibration nuts. 

7. Locate the M8 bolts on last bracket to slot in 
third reflector approx one third distance from 
reflector end. Secure using large washers and 
anti vibration nuts. 
 
8. Slight re-adjustment of brackets may be    
necessary for reflector alignment. Ensure ‘U’ 
bolts are tightened correctly as described in  
section 2.2.3. 
 
 

2.2.7.2.3

 

Four Module Units. 

 

Models 45 and 50 are assembled in two halves. 
 

Working on the half closest to the Burner: 

 
1. Place the first two inner reflectors (H) on the 
heater by sliding the reflectors between the 
tubes and the brackets. 
 
2. Locate the FIRST slot on reflector over the 
M8 bolt on the first bracket on this half. Secure 
using large washers and anti vibration nuts. 
 
3. The slot in other end of the first reflector 
should align with M8 bolts on the second 
bracket on this half. 
 
4. Locate the second reflector onto the same 
bolt using the FIRST slot in from the end and  
OVERLAP the first reflector. This should create 
a 77mm overlap. Secure using large washers 
and anti vibration nuts. 

Ensure the 3rd reflector sits on top 
of the 2nd reflector and the 2nd 

 

 

 

reflector on top of the 1st 

Ensure the 2nd reflector sits on top 
of the 1st. 

Summary of Contents for Vision VSO Series

Page 1: ...1974 or relevant codes of practice In addition the installation must be carried out in accordance with the current IEE wiring regulations BS 7671 BS 6896 Industrial Commercial and any other relevant...

Page 2: ...th and Safety AmbiRad heaters must be installed in accordance with the relevant provisions of the Gas Safety Installations and Use Regulations 1998 Due account should also be taken of any obligations...

Page 3: ...ollowing tools and equipment are advisable to complete the tasks laid out in this manual Suitable alternative tools may be used 2 2 Assembly Notes refer fig s 1 7 2 2 1 Tubes Identify and position tub...

Page 4: ...he heater have been fully assembled and hung in position see Final Fixings section 2 2 7 2 3 All remaining U bolts on the RETURN TUBE should also be tightened to achieve a minimum torque setting of 15...

Page 5: ...A A A A A TWO MODULE THREE MODULE FOUR MODULE 3400mm TUBE 3400mm TUBE 3400mm TURBULATOR 976mm TURBULATOR 2600mm TURBULATOR 976mm TURBULATOR 3040mm TURBULATOR 976mm TURBULATOR 2600mm TURBULATOR 3400mm...

Page 6: ...7 1 Overshield Reflectors Overshields J1 are fitted to the underside of and run in parallel to the inner reflectors One end of the overshield has two holes for direct fixing to the reflector the other...

Page 7: ...IELD 201928 1680 OVERSHIELD 201928 1680 OVERSHIELD 201931 1200 OVERSHIELD 201931 1200 OVERSHIELD BURNER END BURNER END BURNER END AV NUT WASHER CROSS MEMBER OVERSHIELD REFLECTOR WASHER SET PIN EXPANSI...

Page 8: ...second reflector onto the same bolt using the FIRST slot in from the end and OVERLAP the first reflector This should create a 77mm overlap Secure using large washers and anti vibration nuts 5 The slot...

Page 9: ...9 Locate the fourth reflector onto the same bolts using the FIRST slot in from the end and OVERLAP the third reflector This should create a 84mm overlap Secure using large washers and anti vibration...

Page 10: ...21 Page 10 of 20 TWO MODULE THREE MODULE FOUR MODULE 114mm OVERLAP 67mm OVERLAP 77mm OVERLAP 84mm OVERLAP 77mm OVERLAP 50mm OVERLAP WASHER REFLECTOR WASHER REFLECTOR FIXING DETAIL D AV NUT Fig 3 Refle...

Page 11: ...which holds the two halves together Install the outer canopies using the following method 2 2 8 1 Two Module Units 1 Slide on the two halves to cover the 1st section of the heaters and fit closing pla...

Page 12: ...AN VIEW FROM ABOVE HEATER 30mm OVERLAP 30mm OVERLAP 30mm OVERLAP 90mm OVERLAP 30mm OVERLAP 30mm OVERLAP 55mm 35mm E SCRAP PLAN VIEW FROM ABOVE HEATER SCRAP PLAN VIEW FROM ABOVE HEATER FOURTH CANOPY TH...

Page 13: ...ly On VSXO only slide the heat exchanger assembly E1 onto the LEFT HAND TUBE when viewed from behind ensuring it is fully engaged Secure with pinch screws 2 2 13 Fan Assembly On unitary heaters only s...

Page 14: ...e end of the fitting and internally round the end of the tube Enter the fitting into the tube using a slight rotating movement to spread the jointing compound uniformly until a penetration of 75mm 3in...

Page 15: ...J2 Expansion Plate J3 Cross Member K Insulation L Outer Canopy M Canopy End Cap N Closing Plates P End Mouldings optional Ref Description A Radiant Tubes B Suspension Brackets C Return Bend D Coupler...

Page 16: ...nitary heaters E3 Damper Herringbone F1 Forced Burner VSXO F2 Induced Burner VSO G Turbulators Fig 6 Three Module drawings A B C G P J1 J2 D H J3 K L M N F1 F2 E1 E2 E3 H Reflectors J1 Overshields J2...

Page 17: ...unitary heaters E3 Damper Herringbone F1 Forced Burner VSXO F2 Induced Burner VSO G Turbulators H Reflectors J1 Overshields J2 Expansion Plate J3 Cross Member K Insulation L Outer Canopy M Canopy End...

Page 18: ...Doc No 700021 Page 18 of 20 Notes...

Page 19: ...Doc No 700021 Page 19 of 20 Notes...

Page 20: ...cleaning of the reflectors with a soft cloth and a mild detergent non solvent based cleaners only in water can be undertaken Additional removal of dust from the radiant tubes burner and heat exchange...