Ambirad Tornado 600 Operation, Maintenance And Servicing Manual Download Page 11

9

Symptoms

Possible causes

Remedy

Burner will not start

Incorrect voltage selected

Red ‘mains on’ does not illuminate.

Overheat thermostat tripped.

Check outlet and inlets are not obstructed.  Check 
fan speed.  If problem persists replace thermostat.

Red light illuminates.

External controls, thermostats, time switch etc.

Adjust controls.

not calling for heat.
Loose electrical connection.

Check all connections.

Fan seized or faulty motor.

Replace fan, recommission heater, checking gas
pressure settings.

Sequence controller relay failing to pull in and/

Check vacuum switch is satisfactory, replace

or hold in.

sequence controller.

Vacuum switch not returning to normal (switch

Replace vacuum switch.

off) position.

Fan starts but burner does not attempt ignition. Insufficient vacuum generated by fan.

Clean fan blades with soft bristle.

Combustion chamber cover permitting air

Examine condition of sealing gasket, tighten

leakage.

down lid securely.

Vacuum impulse line between combustion

Fix securely in place.

chamber and vacuum switch insecure 
or defective.
Vacuum switch ‘pulls in’ but electronic sequence

Replace burner sequence controller unit but first

controller does not proceed to programme

check that the cause of failure is not a short on

ignition sequence.

output circuit, by measuring resistance between
pins 2 and 7 of burner control unit plug.  A 
reading of 10,000 ohms indicates short circuit on
gas valve burner indicator light or associated 
wiring.

Burner proceeds to ignition stage (normally 

No spark.

Check electrode for cracks – replace if necessary.

indicated by audible spark valve energised

Check high tension connections are secure.

and ‘burner on’ light illuminated) but burner

Check spark gap is 3.5 ± 0.5mm. If no high tension

does not light.

output from electronic controller, replace
controller.

Gas safety valve faulty or defective.

Replace solenoid operator section of gas valve.

Insufficient gas pressure.

Set burner pressure to that indicated on data 
badge (see commissioning).

Burner lights but shuts down after a few

Inadequate flame signal. This can be verified

Replace electrode. Check connections to electrodes

seconds.

by connecting a sensitive micrometer in 

and terminal 4 of electric sequence controller plug

series with the violet wire which passes through

Replace the electronic sequence controller.

the combustion chamber bulkhead. The correct 
reading should be 5µA ± 1µA.
Flame unstable.

Check cleanliness of burner and set burner
pressure as indicated on data badge.

Inadequate gas supply. Observe burner

If gas pressure drops below that indicated on

gas pressure with all heaters operating.

the data badge, examine gas supply pipework
for excessive pressure loss.

Insufficient vacuum at combustion chamber 

Clean fan blades with soft bristle brush.

causing vacuum switch to cut off.

Inspect tube internally and clean if necessary
(see servicing instructions).

Heater shuts down after operating for a period

Refer to above.

If problem persists, replace vacuum switch.

of time.

7  Fault finding

Summary of Contents for Tornado 600

Page 1: ...Operation maintenance and servicing manual Wolfe Design Ltd MOBILE RADIANT HEATERS ...

Page 2: ...h safety details Technical details Moving the product Operating instructions Cleaning maintenance Servicing instructions Fault finding Ducted options Spare parts 3 2 1 4 5 6 7 8 9 MOBILE RADIANT HEATER Index ...

Page 3: ...escaped call the Fire Service After ventilating the room turn off the gas valve and disconnect the electrical connector to the heater If the appliance is hot leave to cool then with the aid of a competent person identify and rectify the source of the leak Gas cylinders This heater is designed to be used with 47kg propane bottles Gas cylinders are heavy never attempt to lift a cylinder full or empt...

Page 4: ...0 volt electrical supply by inserting a suitable connector lead into either the 110 or 230 volt appliance connectors Attach the regulator to the gas bottle using the spanner provided Note Left hand thread Ensure the hose is not twisted or damaged and that the gas bottle is positioned at the side of the unit to avoid heating at the outlet Note When positioning the heater please ensure that all inle...

Page 5: ...rical mains and gas cylinder When heating is complete turn OFF the gas supply Leave the electric supply turned ON to enable the combustion fan to operate for 10 minutes to cool the product prior to moving After cooling is complete switch the 3 position rocker switch Step 7 on the rear of the product to the OFF position and disconnect from the electric supply and remove the electrical connector Dis...

Page 6: ...and flue outlet on the sides of the product are clean and free from any blockage The casing can be cleaned with a soft cloth and a mild detergent as required 5 Cleaning maintenance 6 Servicing instructions Step 1 Place the product on the rear ring in the vertical position to gain access to the fan cover Step 2 Remove the fan access cover Remove the four bolts that attach the fan to the base of the...

Page 7: ...s fixing the rear spinning to the case assembly and the gas hose Step 2 Remove the bolts securing the rear support to the case assembly Step 2 Heat exchanger assembly maintenance Remove the screws fastening the front spinning to case assembly Using a soft brush remove any dust and dirt from the rigid tubes flexible coil and reflector gaining access front and rear of the product Inspect the tube as...

Page 8: ...trode assembly condition taking care when reassembling to ensure that the leads to the assembly are fitted the same way as on removal If the electrode assembly is in good order check the spark electrode gap This should be 3 5mm 0 5mm Adjust the gap if necessary by bending the earth rod Step 6 With a soft brush remove dust from the burner head filter If a blockage is suspected replace the filter by...

Page 9: ...ector carrier and fulham hose nozzle from the gas valve The valve can be replaced and the injector carrier and fulham hose nozzle re fitted using an approved pipe joining compound on the threads of both components Carry out commissioning The governor should be fully screwed in i e put out of action To replace the electronic sequence controller transformer thermostat and pressure switch To remove t...

Page 10: ...8 Figure 1 Vacuum switch connections Figure 2 Wiring diagram MOBILE RADIANT HEATER ...

Page 11: ...s valve burner indicator light or associated wiring Burner proceeds to ignition stage normally No spark Check electrode for cracks replace if necessary indicated by audible spark valve energised Check high tension connections are secure and burner on light illuminated but burner Check spark gap is 3 5 0 5mm If no high tension does not light output from electronic controller replace controller Gas ...

Page 12: ...e flue outlet to the axial fan air stream Secondly attach the rear flue pipe section at the end of the front section as shown above The securing clip can now be tightened to keep both section together In environments where dust moisture or fumes are present a ducted air inlet is provided to allow fresh air to be drawn into the burner to aid combustion and prevent obstruction of the burner mesh wit...

Page 13: ...70 S FAS STA 125 S TOR 600 480 S TOR 600 530 S TOR 600 410 S TOR 600 510 S TOR 600 500 S TOR 600 450 S TOR 600 430 Description Part Number Igniter assembly Burner head mesh Jet carrier Combustion fan Transformer Axial fan c w basket Inlet spinning assembly Outlet spinning assembly Propane regulator Fulham hoze nozzle 3 8 BSPT x 10mm o d Gas hose S TOR 600 420 S ELE TRA 010 S TOR 600 570 S TOR 600 ...

Page 14: ...e position 110 OFF 230volt switch Wheel Rear ring assembly Handle assembly black Controls hinge cover label S TOR 600 630 S TOR 600 300 S TOR 600 560 S TOR WHE 010 S TOR 600 620 S TOR 600 610 S TOR 600 600 S TOR 600 590 S TOR 600 580 S CLI HOS 010 S TOR 600 440 Description Part Number Harness BCH mini Overheat thermostat Capacitor Spanner S TOR 600 670 S TOR 600 640 S TOR 600 460 S TOR 600 520 9 S...

Page 15: ... Facsimile 44 0 1384 489707 Website www ambirad co uk Model Ref HEA TOR PRO 600 For Sales and Service Contact Wolfe Designs Ltd 125 Clydesdale Place Moss Side Industrial Estate Leyland Lancs PR26 7QS Telephone 44 0 1772 456191 Facsimile 44 0 1772 622464 Website www wolfedesigns co uk BCEMA MOBILE RADIANT HEATER UK Patent Applicaion No 0226006 5 ...

Reviews: