background image

 

Version 1.0  

 

©Copyright 2017, Ambient LLC. All Rights Reserved. 

 

 

 

Page 10 

1.

 

If a specific channel is lost, press the 

CH/+

 button to display this channel, then Press and hold 

the 

CH/+

 button for 

3

 seconds, and the remote search icon 

  will be constantly displayed 

for up to 3 minutes. Once the signal is reacquired, the remote search icon 

  will turn off, 

and the current values will be displayed. 

2.

 

If new sensors are added, subtracted, or multiple sensor channels are lost, press and hold the 

CH/+

  button  for 

5

  seconds  (on  any  channel),  and  the  remote  search  icon 

  will  be 

constantly  displayed  for  up  to  10  minutes.  Once  the  signal  is  reacquired,  the  remote  search 

icon 

  will turn off, and the current values will be displayed. 

5.5.2

 

Best Practices for Wireless Communication 

Wireless  communication  is  susceptible  to  interference,  distance,  walls  and  metal  barriers.  We 
recommend the following best practices for trouble free wireless communication. 

1.

 

Electro-Magnetic  Interference  (EMI)

.  Keep  the  console  several  feet  away  from  computer 

monitors and TVs. 

2.

 

Radio  Frequency  Interference  (RFI).

  If  you  have  other  433  MHz  devices  and 

communication  is  intermittent,  try  turning  off  these  other  devices  for  troubleshooting 
purposes.  You  may  need  to  relocate  the  transmitters  or  receivers  to  avoid  intermittent 
communication. 

3.

 

Line of Sight Rating.

 This device is rated at 300 feet line of sight (no interference, barriers or 

walls)  but  typically  you  will  get  100  feet  maximum  under  most  real-world  installations, 
which include passing through barriers or walls. 

4.

 

Metal  Barriers.

  Radio  frequency  will  not  pass  through  metal  barriers  such  as  aluminum 

siding. If you have metal siding, align the remote and console through a window to get a clear 
line of sight. 

 
The following is a table of reception loss vs. the transmission medium. Each “wall” or obstruction 
decreases the transmission range by the factor shown below. 

 

Medium

 

RF Signal Strength Reduction

 

Glass (untreated) 

5-15% 

Plastics 

10-15% 

Wood 

10-40% 

Brick 

10-40% 

Concrete 

40-80% 

Metal 

90-100% 

5.6 Adjustment or Calibration 

Note: 

The  calibrated  value  can  only  be  adjusted  on  the  console.  The  remote  sensor(s)  always 

displays the un-calibrated or measured value. 
 
The purpose  of  calibration  is  to  fine  tune or  correct  for any  sensor  error  associated with  the  devices 
margin of error. The measurement can be adjusted from the console to calibrate to a known source. 
 
Calibration is only useful if you have a known calibrated source you can compare it against, and is 

Summary of Contents for WS-0802

Page 1: ...Defaults 8 5 1 4 Setting the Min and Max Alarm 9 5 2 Backlight Operation 9 5 3 Manually Reset Max Min 9 5 4 Channel Selection 9 5 5 Sensor Transmission 9 5 5 1 Sensor Search Mode 9 5 5 2 Best Practices for Wireless Communication 10 5 6 Adjustment or Calibration 10 5 6 1 Remote Sensor Temperature Calibration 11 5 6 2 Indoor Console Temperature Calibration 11 6 Glossary of Terms 12 7 Specifications ...

Page 2: ...sold separately Item Number Image Description F007T 8 channel sensor measures temperature Applications include indoor and outdoor air temperature measurement F007TP 8 channel sensor measures probe temperature Applications include refrigerators and freezers where the probe is placed inside the appliance s and the display is outside water temperature soil temperature and ground temperature F007PF 8 ...

Page 3: ...nsole Frame Dimensions LxHxW 4 77 x 2 95 x 0 6 in LCD Dimensions LxW 3 00 x 1 17 LCD Segment Height 0 70 inches 1 User Manual 2 2 Thermometer Sensor Set Up Note Do not use rechargeable batteries We recommend fresh alkaline batteries for temperature ranges between 4 F and 140 F and fresh lithium batteries for temperature ranges between 40 F and 140 F 1 Remove the battery door on the back of the sen...

Page 4: ...in Table 1 DIP SWITCH FUNCTION 1 2 3 4 DOWN DOWN DOWN Channel 1 DOWN DOWN UP Channel 2 DOWN UP DOWN Channel 3 DOWN UP UP Channel 4 UP DOWN DOWN Channel 5 UP DOWN UP Channel 6 UP UP DOWN Channel 7 UP UP UP Channel 8 DOWN F UP C Table 1 5 Insert two AAA batteries 6 After inserting the batteries the remote sensor LED indicator will light for 4 seconds and then flash once per 60 seconds thereafter Eac...

Page 5: ...o closing the door Tighten the set screw 3 Remote Sensor Installation It is recommended you mount the remote sensor on a north facing wall in a shaded area Direct sunlight and radiant heat sources will result in inaccurate temperature readings Although the sensor is water resistant it is best to mount in a well protected area such as under an eve Use a screw or nail not included to affix the remot...

Page 6: ...ble unless fully charged and high quality batteries in the back of the display console All of the LCD segments will light up for a few seconds to verify all segments are operating properly 1 Replace the battery door and place the console in the upright position with the desk stand folded out The console will instantly display time and indoor temperature as designated The remote temperature will up...

Page 7: ...cally switch to the normal mode and all further settings can be performed If the remote does not update please reference the troubleshooting guide in Section 8 4 1 Display Console Layout Figure 6 4 2 Sensor Operation Verification Verify the indoor and outdoor temperature match closely in the same location about 5 to 10 apart The sensors should be within 2 F the accuracy is 1 F Allow about 30 minut...

Page 8: ...The time alarm icon will appear when set and disappear when disabled SET Alarm Minute Press the or key to increase or decrease the alarm minute While the alarm value is flashing press and hold the SET button for three seconds to toggle the alarm on and the alarm off The time alarm icon will appear when set and disappear when disabled SET Temperature Units of Measure Press the key to switch between...

Page 9: ...on to decrease the LOW alarm Press and hold the or button to change rapidly While the alarm value is flashing press and hold the SET button for three seconds to toggle the alarm on and off the alarm The alarm icon will appear when set and disappear when disabled 5 2 Backlight Operation To temporarily turn on the back light for five seconds press the any button on the indoor sensor 5 3 Manually Res...

Page 10: ...ry turning off these other devices for troubleshooting purposes You may need to relocate the transmitters or receivers to avoid intermittent communication 3 Line of Sight Rating This device is rated at 300 feet line of sight no interference barriers or walls but typically you will get 100 feet maximum under most real world installations which include passing through barriers or walls 4 Metal Barri...

Page 11: ... 6 2 Indoor Console Temperature Calibration To enter the indoor temperature calibration mode press and hold the SET and MIN MAX buttons at the same time for 5 seconds and the INDOOR temperature value will begin flashing Press the CH button to increase the temperature and the MIN MAX button to decrease the temperature reading in 0 1 increments To rapidly increase or decrease the temperature reading...

Page 12: ...7 2 Measurement Specifications The following table provides specifications for the measured parameters Measurement Range Accuracy Resolution Indoor Temperature 32 to 140 F 2 F 0 1 F Channel 1 8 Temperature 40 to 140 F 2 F 0 1 F 7 3 Power Consumption Base station display console 2 x AAA 1 5V Alkaline or Lithium batteries not included 2 x AAA 1 5V Alkaline or Lithium batteries not included Battery l...

Page 13: ...range is 300 and 100 under most conditions Move the sensor assembly closer to the display console If the sensor assembly is too close less than 5 move the sensor assembly away from the display console Make sure the remote sensor LCD display is working and the transmitter light is flashing once per 60 seconds Install a fresh set of batteries in the remote thermo hygrometer For cold weather environm...

Page 14: ...tions This product is not to be used for medical purposes or for public information The specifications of this product may change without prior notice This product is not a toy Keep out of the reach of children No part of this manual may be reproduced without written authorization of the manufacturer Ambient LLC WILL NOT ASSUME LIABILITY FOR INCIDENTAL CONSEQUENTIAL PUNITIVE OR OTHER SIMILAR DAMAG...

Page 15: ...purchaser of this product To receive warranty service the purchaser must contact Ambient LLC for problem determination and service procedures Warranty service can only be performed by a Ambient LLC The original dated bill of sale must be presented upon request as proof of purchase to Ambient LLC Your Ambient LLC warranty covers all defects in material and workmanship with the following specified e...

Reviews: