Operation
19
LED
Mode
Charge level: 5 bars are displayed, frame is displayed continuously: The
battery is fully charged.
Trickle charging for a fully charged battery.
Fault: Defective battery
Fault: reversed terminal clamps
Fault: no battery connected, short circuit
6 V / 0.8 A charging mode (6 V batteries up to max. 14 Ah)
You can identify the battery type from the type plate on your battery.
The charger will normally recognise the 6 V standard charging mode suitable for the
battery type. If the battery is not recognised, proceed as follows:
− Set this mode to charge 6 V lead acid batteries with a capacity under 14 Ah.
− Press the
MODE
1
button several times to select mode
6 V / 0.8
.
The
10
symbol is shown on the display
2
.
If you do not then set another mode, the electronics automatically start the charging
process with a charging current of around 0.8 A.
Once the battery is fully charged, the frame around the battery icon
11
stops fl ashing
and the entire battery icon lights up continuously. Trickle charging takes place in this
state.
12 V / 0.8 A charging mode (12 V batteries up to max.
120 Ah)
You can identify the battery type from the type plate on your battery.
The charger will normally recognise the 12 V standard charging mode suitable for the
battery type. If the battery is not recognised, proceed as follows:
− Set this mode to charge batteries with a capacity under 120 Ah.
− Press the
MODE
1
button several times to select the 12 V / 0.8 A mode.
18559 EN-AS MSN 50059506-50060404 Content RC3.indd 19
18559 EN-AS MSN 50059506-50060404 Content RC3.indd 19
29.06.2018 08:43:11
29.06.2018 08:43:11
Summary of Contents for md18559
Page 1: ...CAR BATTERY CHARGER User Manual...