10. Restart Device
If
GPRS is abnormal (device is offline), user can send SMS command
RESET#
to restart
the device. Device will reboot after 20 seconds after receiving the command.(See command
list 7-17)
11. Door Detection
The device is able to detect door status. It uploads car status to platform and APP timely.
Negative triggering is default. When car door's status is negative triggering, there is no need
to
set. Instead, if car door status is positive triggering, the triggering way has to be modified.
(Command:
DOOR, 1#
). See 3.2 diagram-1 for wiring way. (See command list 7-18)
Notice
Negative triggering (default): when door Is open, signal level of door is OV; when door is
closed, signal level of door is power voltage. Positive triggering: when door is open, signal
level of door is power voltage; when door is closed, signal level of door is OV.
12. Analog Signal
The device can measure car battery’s voltage and upload It to platform/APP in fixed time
based on your needs. Purple line (ADC) of device extended port can receive analog signal,
like voltage of external device, analog temperature sensor and fuel sensor. Voltage range of
analog input is 0-30Vdc. See 3.2 diagram for wiring way. (See command 11st 7-19)
13. Lithium battery charging protection
Built-In battery won't be charged when the temperature Is over 50"C or less than -20°.
As
soon as the temperature is lower than 46"C or above -18°, battery charging will be
restored.
14. Controllable Output
The device supports high/low level output, which could be configured by commands based
on
needs.
6. Platform Operation
Get registered on the designated service platform by authorized dealer, then you can start the
tracking service and settings.