background image

 

 

 

Know your device 

 

 

AIT 210 Device view 

Pinout 

 

AIT20 2x6 socket pinout 

 

Pin 

number 

Pin name 

Description 

VCC (10-30) V DC (+)  

Power supply (+10-30 V DC).  

DIN 3 / AIN 2  

Analog input, channel 2. Input range: 0- 30 V DC / Digital 
input, channel 3.  

DIN2-N / AIN1  

Digital input, channel 2 / Analog input, channel 2. Input 
range: 0-30 V DC /GND Sense input  

DIN1  

Digital input, channel 1.  

CAN2L  

CAN LOW, 2nd line  

CAN1L  

CAN LOW, 1st line  

GND (-)  

Ground pin. (10-

30) V DC (―)  

DOUT 1  

Digital output, channel 1. Open collector output. Max. 0,5 
A DC.  

DOUT 2  

Digital output, channel 2. Open collector output. Max. 0,5 
A DC.  

10 

1WIRE DATA  

Data for 1

–Wire devices.  

11 

CAN2H  

CAN HIGH, 2nd line  

12 

CAN1H  

CAN HIGH, 1st line  

AIT 210 2x6 socket pinout 

 

Summary of Contents for AIT210

Page 1: ......

Page 2: ...l input channel 2 Analog input channel 2 Input range 0 30 V DC GND Sense input 4 DIN1 Digital input channel 1 5 CAN2L CAN LOW 2nd line 6 CAN1L CAN LOW 1st line 7 GND Ground pin 10 30 V DC 8 DOUT 1 Dig...

Page 3: ...Wiring scheme AIT210 Wiring scheme Set up your device How to insert Micro SIM card and connect the battery Cover removal Micro SIM card insert Battery connection Attaching cover back...

Page 4: ...power might be still available on the power wires Depending on the car model this may happen in 5 to 30 minutes period 2 When the module is connected measure the voltage again to make sure it did not...

Page 5: ...Receiver Tracking 33 Tracking sensitivity 165 dBM Accuracy 3 m Hot start 1 s Warm start 25 s Cold start 35 s Cellular GSM GSM 2G bands Quad band 850 900 1800 1900 MHz Data transfer GPRS Multi Slot Cla...

Page 6: ...hboard Total fuel consumption Vehicle speed wheel Vehicle driven distance Engine speed RPM Accelerator pedal position Sensors Accelerometer Scenarios Green Driving Over Speeding detection Jamming dete...

Page 7: ...urement error on 12V Range 1 0 9 Additional error on 12 V Range 1 108 mV Measurement error on 30 V Range 1 0 33 Additional error on 30 V Range 1 88 mV Input Voltage Recommended Operating Conditions Ra...

Page 8: ...r supply should be disconnected Before un mounting the device from the vehicle the 2x6 connector must be disconnected The device is designed to be mounted in a zone of limited access which is inaccess...

Page 9: ...rranty Amber connect guarantees its products to be free of any manufacturing defects for a period of 24 months With additional agreement we can agree on a different warranty period for more detailed i...

Page 10: ......

Reviews: