background image

Instructions for Use & Installation

QUADRO COLLECTION

CONSULT THIS INSTRUCTION MANUAL IN ITS ENTIRETY PRIOR TO 
THE HANDLING & INSTALLATION OF ANY TOWEL WARMER

FOLLOW THE GENERAL GUIDELINES & INCLUDED WIRING DIAGRAM.

790 Pickens Industrial Dr,

Marietta, GA 30339 USA

Phone : (404) 350 9738

Fax : (404) 355 0166

www.ambaproducts.com

3165407

IP 54

SKU

Width HEIGHT Power

Amps

BTU

Q2016

20 1/2”

16 3/4”

92 watts

0.8

314

Q2033

20 1/2”

33 1/4”

172 watts

1.5

586

Q2042

20 1/2” 42 5/16” 232 watts

2.0

791

Q205

4

20 1/2”

54 1/2”

296 watts

2.6

1009

Q2833

28 3/8”

33 1/4”

232 watts

2.0

791

Q2842

28 3/8”

42 3/8”

296 watts

2.6

1009

COMPONENTS

1

2

3

4

5

6

8

7

1 – Plastic Anchor
2 – Threaded Wall Support
3 – Anchor Screw 
4 – Threaded Long Tube

5 – Cover
6 – Setscrew
7 – Fixing Screw
8 – Bushing

DIGITAL HEAT CONTROLLER

Please see Instructions;

DHC Included on all models excluding Q2016; 

See switch guide (pg.

7

)

110v

Summary of Contents for emmesteel QUADRO Q2016

Page 1: ...SKU Width HEIGHT Power Amps BTU Q2016 20 1 2 16 3 4 92 watts 0 8 314 Q2033 20 1 2 33 1 4 172 watts 1 5 586 Q2042 20 1 2 42 5 16 232 watts 2 0 791 Q2054 20 1 2 54 1 2 296 watts 2 6 1009 Q2833 28 3 8 33...

Page 2: ...red The unit has to be connected to a power supply circuit equipped with an omni polar disconnection electrical system with a distance among contacts of 1 8 Caution high temperature risk of fire keep...

Page 3: ...uring normal operations are maintained below the temperature of 60 65 c 140 149 f without towels and 90 c 194 f with towels as required by following standards For residue buildup do not use extreme pr...

Page 4: ...tural members behind the drywall If not possible on both sides toggle bolts can be used on one side Proceed laying the threaded wall support point 2 on the hole and fasten it with the anchor bolt scre...

Page 5: ...r use only Ensure that room trip switch is off before any operation Wrong wiring connection to the power source will cause sparks and the burning damage to the digital heat controller carefully consul...

Page 6: ...C Output cable D Towel Warmer cable E Ground faston POWER REGULATOR 1 Connect T1 A T2 B T3 D to faston T E 2 Connect L 1 A L2 B 3 Connect N 1 A N2 8 4 Connect N3 0 N4 C 5 Connect L3 0 L4 C Level Setti...

Page 7: ...the fastenings of the towel warmer s cable to the other section See the example below Connect one cable to the left section Electrical bridge 1 1 2 2 Connect the other cable to the right Electrical b...

Reviews: