INSTALLATION

INSTRUCTIONS

CAUTION: 

DO NOT TAKE OFF THE PROTECTIVE P.V.C. TAPE BEFORE INSTALLING TOWEL WARMER TO 
AVOID SCRATCHING, MARKING OR GRAZING THE SURFACE. 

Setscrew

Threaded 

Long Tube

• 

Take the threaded long tube ( point 3) and screw 
it down completely to the threaded wall-support 
(point 2) ; to adjust the distance from wall 
unscrew tube(point 3) 

Brick Wall

Plastic 

Anchor

Brick wall:

• 

Drill the holes in the wall ø6 mm ( 1/4 inches) 
and put the plastic anchor (1) into the wall;

Drywall:

• 

Leave out the plastic anchor (1) and proceed 
with step 2

STEP 1

STEP 3

STEP 5

STEP 6

STEP 2

Drywall

Anchor 

Screw

Drywall:

• 

Fasteners should be fixed to studs or structural 
members behind the drywall

• 

If not possible on both sides, toggle bolts can 
be used on one side.

• 

Proceed laying the threaded wall-support 
(point 2) on the hole and fasten it with the 
anchor bolt screw: repeat this procedure also 
for the other points marked on the wall

Fixing Screw

Bushing

BACK SIDE OF 

TOWEL WARMER

• 

Laythe bushing (point 6) on the holes of the towel 
warmer. And fasten it with the fixing screw (point 5); 

• 

Repeat this procedure also for the other connecting 
holes of the towel warmer.

• 

Install the towel warmer in the four connections as 
shown in drawing. Technical Drawings can be found 
on our website www.Ambaproducts.com

• 

For each leg fasten the Setscrew and place the 
cover onto the bracket

Threaded Wall-

Support

STEP 4

INSTALL DIGITAL HEAT CONTROLLER OR 
SWITCH — SEE PAGES 7 OR 8.

REMOVE THE PROTECTIVE P.V.C. TAPE BEFORE 

SWITCHING THE TOWEL WARMER ON

Summary of Contents for emmesteel QUADRO Q2016

Page 1: ...SKU Width HEIGHT Power Amps BTU Q2016 20 1 2 16 3 4 92 watts 0 8 314 Q2033 20 1 2 33 1 4 172 watts 1 5 586 Q2042 20 1 2 42 5 16 232 watts 2 0 791 Q2054 20 1 2 54 1 2 296 watts 2 6 1009 Q2833 28 3 8 33...

Page 2: ...red The unit has to be connected to a power supply circuit equipped with an omni polar disconnection electrical system with a distance among contacts of 1 8 Caution high temperature risk of fire keep...

Page 3: ...uring normal operations are maintained below the temperature of 60 65 c 140 149 f without towels and 90 c 194 f with towels as required by following standards For residue buildup do not use extreme pr...

Page 4: ...tural members behind the drywall If not possible on both sides toggle bolts can be used on one side Proceed laying the threaded wall support point 2 on the hole and fasten it with the anchor bolt scre...

Page 5: ...r use only Ensure that room trip switch is off before any operation Wrong wiring connection to the power source will cause sparks and the burning damage to the digital heat controller carefully consul...

Page 6: ...C Output cable D Towel Warmer cable E Ground faston POWER REGULATOR 1 Connect T1 A T2 B T3 D to faston T E 2 Connect L 1 A L2 B 3 Connect N 1 A N2 8 4 Connect N3 0 N4 C 5 Connect L3 0 L4 C Level Setti...

Page 7: ...the fastenings of the towel warmer s cable to the other section See the example below Connect one cable to the left section Electrical bridge 1 1 2 2 Connect the other cable to the right Electrical b...

Reviews: