Using the machine
•
The agitator normally remains switched on from filling to the end
of spraying operation. On this account, the instructions of the
agent manufacturer are decisive.
•
If there is a sudden significant drop-off in spray pressure, the
spray liquid tank is empty.
•
Residues in the spray liquid tank can be applied correctly up to a
pressure drop of 25%.
•
If the spray pressure drops off while conditions remain otherwise
unaltered, the suction or pressure filter are blocked.
11.7.1
Applying the spray liquid
•
Properly couple the field sprayer to the tractor.
•
Before starting spraying, check the following machine data on
the operating terminal
ο
the values for the permitted spray pressure range of the
spraying nozzles installed in the sprayer boom.
ο
the value "Pulses per 100m".
•
Check the indicated spray pressure during spraying operation.
Control terminal / AMASPRAY
+
: Ensure that the indicated spray
pressure does not deviate under any circumstances by more
than
±
25 % from the target spray pressure given in the spray
table, e.g. by changing the spray rate using the plus/minus but-
tons. Larger deviations than this from the target spray pressure
make it impossible to achieve the best possible results from your
crop protection measure and cause pollution of the environment.
•
Decrease or increase the operational speed until you are back
within the permissible spray pressure range for the target spray
pressure.
•
Never keep spraying until the spray liquid tank is empty (does
not apply at the end of spraying operation). Refill the spray liquid
tank before the fill level reaches approx. 50 litres.
•
At the end of spraying operation, when the fill level falls below
approx. 50 litres, switch off the agitator.
Example:
Required spray rate:
200 l/ha
Intended operational speed:
8 km/h
Nozzle type:
AI
Nozzle size:
'05'
Permissible pressure range for the
spraying nozzle when fitted:
min. pressure 2 bar
max. pressure 7 bar
Target spray pressure:
3.7 bar
Permissible spray pressure: 3.7 bar
±
25
%
min. 2.8 bar and max. 4.6 bar
UF BAG0012.11 04.19
155
Summary of Contents for UF 1201
Page 19: ...General safety instructions Super S boom Fig 4 Q Plus boom Fig 5 UF BAG0012 11 04 19 19 ...
Page 204: ...Liquid circuit 14 Liquid circuit single nozzle control 204 UF BAG0012 11 04 19 ...
Page 205: ...Liquid circuit Part width section control UF BAG0012 11 04 19 205 ...
Page 210: ...Spray table Fig 157 210 UF BAG0012 11 04 19 ...
Page 219: ...Spray table UF BAG0012 11 04 19 219 ...
Page 220: ......