background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Amalog

Page 1: ...Operating Instructions On Board Computer 0 2 MG 715 DB 550 1 GB 05 03 Printed in Germany a Before starting to operate please carefully read and adhere to this operation manual and safety advice ...

Page 2: ...Copyright 2003 AMAZONEN WERKE H DREYER GmbH Co KG D 49502 Hasbergen Gaste Germany All rights reserved ...

Page 3: ...g 12 5 2 Entering implement specific data 12 5 2 1 Mode 1 free function 12 5 2 2 Mode 2 Number of track marker sensors 13 5 2 3 Mode 3 Select implement type 14 5 2 4 Mode 4 option Enter the period of time between the incidence of a fault and the release of the alarm 15 5 2 5 Mode 5 option Set the period of time until an order is carried out 16 5 2 5 1 Entering the implement specific data 17 5 2 5 ...

Page 4: ...ceipt of the computer please check for transport damage or whether any parts are emitting Only immediate claims to be filed with the forwarding agency may lead to replacement Scope of delivery 1 Computer 2 Console 3 Battery cable special option NE190 1 2 3 25A ...

Page 5: ... operation as a display and monitoring device for agricultural machinery Any use other than that stipulated above is no longer regarded as designed use The manufacturer does not accept any responsibility for damage resulting from this Therefore the operator himself will carry the full risk Under designed use the operator must adhere to the manufacturer s prescribed operation maintenance and repair...

Page 6: ...ral danger symbol Safety symbol according to DIN 4844 W9 3 3 2 Attention symbol I Attention symbols which may cause dangers for the machine and it s function when not being adhered to are identified with the Attention symbol 3 3 3 Hint symbol F Hints regarding machine s specific particularities which have to be adhered to for a faultless function of the machine are identified with the hint symbol ...

Page 7: ...th For cabling and installation as well as for the maximum permissible current supply in addition adhere to the fitting instructions of the implement manufacturer 3 5 Safety advice for repair work I Before carrying out any repair work on the electric system or arc welding on the tractor or the mounted implement disconnect all connections of AMALOG ...

Page 8: ...le alarm is given and the rev speed is shown on the display t as hectare counter determines the finished part area ha and stores the finished total area ha AMALOG is provided with a memory and a lithium battery All entries and calculated values remain stored for approx 10 years even if the on board power supply has been switched off They are available again for the next operation 4 3 Functions AMA...

Page 9: ...erating display appears Operating display Forward speed km h Position of the tramline counter Track marker left hand side in operating position Track marker right hand side in operating position the forward switching of the tramline counter is locked The seed box is empty finished area or part area Fault message speed ...

Page 10: ...rating display Indication of the blower fan speed Indicating or entering the working width m Indicating or entering the ground related sensor impulses over a distance of 100 m Pressing the key prevents the automatic counting up the tramline counter Indicating or entering the current switching rhythm Entering the blower fan desired speed Switching forward the tramline counter ...

Page 11: ...11 AMALOG DB 550 1 05 03 Input key for increasing the displayed value Input key for decreasing the displayed value Key used to confirm all entries Correction key ...

Page 12: ...esired direction by one step forward or backward By repeated pressure onto the same key the display continues to run until the key is released I All entering via the keys and all calibration procedures must always be confirmed by pressing key and stored this way I Before starting to operate check all implement specific entered data F Already entered implement specific data remain stored 5 2 1 Mode...

Page 13: ...cted time the tramline counter does not go on counting Seed drill with one track marker sensor an the hydraulic valve Seed drill with two track marker sensors Press key hold an simultaneously press key to unlock this way the entering Mode 2 Press key if necessary confirm repeatedly and dial Mode 2 Display after having dialled Mode 2 The first figure shows the dialled Mode 2 the second figure 00 me...

Page 14: ...eously press key to unlock the input Mode 3 Press key if necessary press repeatedly and select Mode 3 Display after having selected Mode 3 The first figure 3 shows the chosen Mode 3 the second figure 01 the connected pneumatic seed drill Via the keys or select the coding 00 or 01 on the display Press key to store the selected value e g and to secure against unintended change ...

Page 15: ... drills set 10 seconds For setting the period of time Press key keep pressed and simultane ously press key in order to unlock the mode entering Press repeatedly until the display mode 4 Fig 2 appears Fig 2 The first figure shows the selected mode 4 the second figure shows the period of time e g 22 sec see Fig 3 between the incidence of a fault on the tramlining kit or the counter shaft and the rel...

Page 16: ...d of time Press key keep pressed and simultane ously press key in order to unlock the mode entering Press key repeatedly until the display mode 5 Fig 5 appears Fig 5 The first figure shows the selected mode 5 the second figure shows the period of time e g 22 sec Fig 6 which may pass e g on conventional seed drills from the moment of the order to create tramlines until the standstill of the counter...

Page 17: ...o determine the calibration figure by driving a calibration distance 1 The calibration figure Imp 100m is known F The calibration value Imp 100m depends on the seed drill type used the place the sensor has been fixed to the prevailing soil conditions Press key whilst the implement is not moving Take the known calibration figure Imp 100m from Table 2 and dial with the keys or Display of the dialled...

Page 18: ...bration test pneumatic Pack Top seed drills pneumatic tyre packer Pack Top seed drills Pack Top seed drills Tyre packer Pack Top seed drills AD P02 RP AD P02 AD03 RP AD03 crank turns on the star wheel Ø 1 18 on the intermediate drive on the star wheel on the intermediate drive working width m 1 40 ha 2 5 27 0 59 0 27 0 59 0 3 0 22 5 49 0 22 5 49 0 4 0 17 0 37 0 17 0 37 0 4 5 15 0 33 0 15 0 33 0 Se...

Page 19: ... Super and D9 Special D9 Super D9 Special AMALOG Impuls 100m mean value Crank turns on the wheel Tyres working width m 1 40 ha 2 5 46 0 6 00 16 3 0 38 5 740 3 0 37 0 10 0 75 15 4 0 28 0 711 3 0 37 0 31x15 5 15 Mitas 4 0 28 0 711 ...

Page 20: ...y Display during the calibration test Stop after 100m On the display now the number of impulses e g 1005 is shown which had been determined while travelling the calibration distance Auf 100m Press key and this way store the displayed determined calibration figure Imp 100m Press key once again and check the stored calibration figure The display should now show the determined calibration figure e g ...

Page 21: ...r Imp 100m table 2 1005 Conversion factor 1053 0 95 Number of crank turns actual 22 5 x 0 95 21 4 5 2 5 1 2 Enter the working width For determining the worked areas AMALOG requires the information of the working width To enable it enter the working width as follows Press key Dial the desired working width m by pressing keys or e g 3 00 for 3 m working width Display working width Press key and stor...

Page 22: ...ed drill 3m working width Fertiliser broadcaster field sprayer 24m working width 24m tramline spacing Please look up the chapter metering wheel tramlining control of the seed drill s instruction book Table 4 Excerpt of the instruction book seed drill 8 4 6 7 0 2 1 3 4 6 5 7 0 5 A B C D A Working width of the seed drill B Tramline spacing C Control rhythm D Tramline counter controlled and displayed...

Page 23: ... control rhythm stored up to now Pre select the required control rhythm via the keys or e g 8 Press key and store the pre selected value e g 8 Thereafter the following display is shown Display with the newly entered control rhythm F The control rhythms provided by AMALOG are mentioned in table 5 ...

Page 24: ...7 7 8 8 7 7 7 8 9 0 8 8 8 10 10 9 9 9 10 10 10 11 11 11 12 12 Tramline counter controlled and displayed by the on board computer 13 Control rhythm 15 16 17 20 21 22 23 26 1 0 0 0 0 0 0 0 2 1 1 1 0 0 0 1 3 2 2 2 1 1 1 2 4 3 3 3 2 2 2 3 5 4 4 4 3 3 3 4 6 5 5 5 4 4 4 5 7 6 6 6 5 5 6 8 7 7 7 6 6 7 9 8 8 8 7 8 10 9 9 9 8 9 11 10 10 10 12 11 11 13 12 12 14 13 13 15 14 14 15 15 16 Tramline counter contro...

Page 25: ...r to beginning the operation via key and select this way the figure which under the word START is shown for this please refer to para 5 2 5 1 3 e g 4 Display when advancing the tramline counter stationary F The hydraulically actuated marker change over for the markers is coupled with the sensor for the tramlining control Pay attention that the automatic marker change over lowers the desired marker...

Page 26: ... track markers e g at obstacles the advancing of the tramline counter must be prevented For this press key prior to interrupting the sowing operation or prior to folding in the track markers and thus prevent the advancing of the tramline counter Display after having pressed the Stop key F After having pressed key the tramline counter 3 flicks in the operational display and indicates that the advan...

Page 27: ...isplayed which has been operated on after having released the start function F Only the worked area will be determined during which the implement had been in operating position Display after one time pressing the key 2 Hectare meter total area After pressing key twice the total area in ha is displayed This counter cannot be erased Display after pressing the key twice After three times pressing key...

Page 28: ... undercutting the nominal speed F The rev monitoring is only active in operational position F After ending the rev speed monitoring it should be switched off again Entering the nominal speed Press key yellow The pre set nominal speed will appear on the display Change the nominal speed accordingly via the keys or Press key and store the selected nominal Switching off the rev speed monitoring Press ...

Page 29: ...29 AMALOG DB 550 1 05 03 ...

Page 30: ...30 AMALOG DB 550 05 03 ...

Page 31: ......

Page 32: ... DREYER GmbH Co KG Postfach 51 D 49202 Hasbergen Gaste Germany Tel 49 0 54 05 50 1 0 Telefax 49 0 54 05 50 11 93 e mail amazone amazone de http www amazone de D 27794 Hude D 04249 Leipzig F 57602 Forbach ...

Reviews: