background image

NITID S12W 

 

   Dec 2022 

 

 
 

7

 

 

       Amate Audio

 

 
 

 
 

 
 
 
 

Fig. 6. 

Back energy rejection at 40 Hz / 50 Hz / 63 Hz

 

 
2.

 

CONTROL AND CONNECTION PANEL 

The S12W control panel contains the following elements: 

 

A) TOUCHSCREEN: 

Displays  information  about  the  System  status:  current  preset, 

amplifier  status  and  signal  input  level.  Allows  the  user  to  configure  the  system: 
Preset  selection,  Delay,  Gain,  Limiter,  polarity,  ECO  mode  on/off,  Front  LEDs 
on/off, etc. For more information about the available functionality, read the Annex I 
of this manual. 

NOTE:

 For preventing the access to Main Menu with a PIN pattern, please refer to 

Annex I. 

 

B) MODEL DATA: 

The basic data of the model is found here:  

- Model reference 
- Amplifier program power (Watts) 
- Maximum Sound Pressure Level Continuous delivered by the system (dB SPL) 

 
C) BALANCED INPUT/LINK:  

XLR-3 Female balanced signal connector for signal input. 
XLR-3 Male connector for parallel connection of various cabinets with the same input 
signal. 
Nominal Input sensitivity: +2dBu (1 Vrms) 
Maximum Input Voltage without clipping: +14dBu (4Vrms) 
Maximum Input Voltage: +20dBu (8Vrms)  

 

IMPORTANT:

  Please  always  use  balanced  microphone  cable  with  the 

following pin assignment: 1= Shield (Ground)   2= Live (+)    3= Return (-) 

 

D)

 

AC MAINS INPUT/LINK:

 Mains supply connection via PowerCon.  

  Blue connector for AC in. 

  Grey  connector  to  feed  other  units  in  parallel.  Linking  up  to  ten  units  is 

possible,  if  a  quality  cable  of  a  minimum  section  of  3x2.5mm

2

  is  used. 

Connecting  more  than  ten  units  in  parallel  may  lead  to  a  voltage  drop  in  the 
cable that will reduce the equipment performance. 

 
Always  use  mains  power  cable  supplied  by  manufacturer.  Never  connect 
NITID  cabinets  to  an  unearthed  mains  supply  or  by  using  an  unearthed 
mains cable 

 

 
 
 

Summary of Contents for Nitid S12W

Page 1: ...User s manual December 2022...

Page 2: ...cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 10 The equipment must be repaired by qualified technical service pe...

Page 3: ...ls presets parametric EQs delay mute gain polarity and limiter ECO mode available automatic standby mode controlled by the input signal Amplifier self diagnostics input and output level temperature li...

Page 4: ...id presets The S12W enables the combination of three or multiple of three subwoofer cabinets in an array to provide exceptional directivity at low frequencies High directivity at low frequencies has t...

Page 5: ...nergy of the back and not the one of the front This can only be achieved with cabinets that incorporate independent delay units on their DSP as the X218WFD Fig 2 Cardioid pattern 1 3 4 Configuration w...

Page 6: ...PF100 STANDARD Generic HPF 100 Hz CARD S ALIGNED S ALIGNED S26 S10 S12 HPF90 Hz Fig 4 Correspondence of rear and front presets for cardioid applications IMPORTANT NOTE Due to the internal set up of th...

Page 7: ...the system dB SPL C BALANCED INPUT LINK XLR 3 Female balanced signal connector for signal input XLR 3 Male connector for parallel connection of various cabinets with the same input signal Nominal Inp...

Page 8: ...code is a smart label that ensures that the product is an original Amate Audio product To verify the authenticity please follow the instructions in the following link http www amateaudio com en produc...

Page 9: ...he other end Fig 8 Parallel connection for S12W cabinets signal and mains Do not connect NITID series units using PowerCon without earth Do not connect more than ten units using the AC output link con...

Page 10: ...eck that the signal cables are in good condition and connected at both ends The mixer output level must not be at minimum Check that the mixer channel is not muted Check that the system is not in MUTE...

Page 11: ...ting devices Check there is no light intensity regulator in the same AC circuit as the unit ALWAYS connect the sound and light circuits in different phases Check that there is a proper connection to E...

Page 12: ...PF100 Maximum output level 1m continuous 126 dB Amplifier program 1000 W Nominal directivity 6dB omnidirectional Components LF MF 12 woofer 3 voice coil Cabinet Type Band pass Height 384 mm Width 520...

Page 13: ...ion angle 180 16 7 Million of colours 1 Main screen After turning on the system a first loading screen show up the Amate Audio s logo The built in gyroscope can adapt the orientation of the screen ele...

Page 14: ...n D Settings PIN E Info button Info button is dynamic meaning that it changes according to the unit s status The button shows current temperature with three colours Blue when temperature is below 55 o...

Page 15: ...dB of headroom In the case the signal reaches saturation a red clipping indicator show up G Limiter check Gain reduction level meter The limiter check box LIM box turns on when the integrated signal l...

Page 16: ...ct the gain reduction applied to the input signal o Limiter Built in limiter threshold control The level meter shows the current gain reduction applied to the input signal Lower the threshold to incre...

Page 17: ...available EQ will be set back to factory default no EQ The system will ask for confirmation before performing this operation with an on screen window Select OK to proceed o Save Access to the internal...

Page 18: ...ns are OFF LED always off ON LED always on LIM ON LED remains off until internal limiter starts working that makes LED lights on LIM OFF LED remain on until internal limiter starts working that makes...

Page 19: ...n PIN can be reset anytime Just hold the finger on the screen when unit boots on the Amate Audio logo When boot finish the pattern have been reset to default 2 3 Advanced menu o Sweep Acoustic test A...

Page 20: ...9 FCC Part 15 WARNING In accordance to EN55022 this is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate mea...

Page 21: ...lona SPAIN by Amate Audio S L Perpiny 25 Pol gon Industrial Nord 08226 Terrassa T 34 93 735 65 65 F 34 93 735 60 48 info amateaudio com R D and FACTORY Violinista Vellsol 18 08222 Terrassa T 34 93 736...

Reviews: