PRODUCT IDENTIFICATION
6 Rev 1
This section will identify the models that are covered and the changes per each model group from one release to the next.
Model #
Manufacturing #
Description
ASC01A
P1200601C
A
nti
S
hort Cycle
K
it. Kit contains a 3 minute off cycle timer to prevent short cycling of the
compressor. Factory installed in RCE, RHE units with scroll compressors. Also included in
PCK__A pressure control kits.
ATK05A
P6443902C
A
mbient
T
emperature
K
it. Kit is designed for heat pump applications to prevent energizing
auxiliary electric heating elements when the ambient temperature is above set point. Also included
in FFK__A Fossil Fuel Kits.
CSB__A
P1176802C - P1176809C
C
ompressor
S
ound
B
lanket kit. Reduces the operation sound transmitted through the air by the
compressor. Factory installed in many of the higher efficiency models.
HSK__A
P1180002C - P1180014C
H
ard
S
tart
K
it. Hard start kits dramatically increase the starting torque of compressors.
Recommended for use in systems which use TXV valves to control refrigerant flow.
FSK01A
P1207101C
(
FS
)Freeze Protection
K
it. Installed on indoor coils, kit prevents compressor operation when coil
temperature drops below 32 degrees.
PCK__A
P1180101C - P1180103C
P
ressure
C
ontrol
K
it. Kit includes hi and low pressure switches, necessary connectors, and anti
short cycle timer. Higher efficiency models have these components factory installed.
LAC__A
P1180103C - P1180106C
L
ow
A
mbient
C
ontrol kit. Allows cooling operation in ambient temperatures between 50 degrees
and 32 degrees. This kit is for TXV systems only. Not designed for ambient below 32 degrees.
LSK01A
P1206901C
L
iquid line
S
olenoid
K
it. This kit improves system efficiency and prevents compressor oil
migration in the off cycle. Recommended for installations where oil migration could occur.
Compressor must have a Hard Start Kit when this kit is used.
FFK__A
P1122302C - P1122303C
F
ossil
F
uel
K
it. Fossil fuel kits are designed for heat pump installations with gas or oil furnaces as
the back up or reserve heating system. The FFK02A will not function correctly on RHA__B_A heat
pumps. However, the FFK03A is backward compatible to all RHA, RHD or RHE heat pump
systems.
ROK__A
P1208401C -P1208417C
R
estrictor
O
rifice
K
it. ROK01A contains an assortment of "Aeroquip" orifices. ROK49A - ROK98A
contain 3 ea. of "Chatleff" orifices, the kit number indicates the orifice size. See model/accessory
list for correct kit for specific coil model.
TXV__A
P1206501C - P1206503C
P1234601C - P1234603C
T
hermo-e
X
pansion
V
alve Kit. Improves the efficiency of restrictor orifice style coils. Valves are
heat pump compatible. See model/accessory list for correct kit for specific coil model
DSK01A
P1187207C
D
i
S
connect
K
it. This kit is designed to be used with BCA/BHA air handlers with 5, 7, or 10 kW
electric heat only.
SPK__A
P1208801C - P1208802C
S
ingle
P
oint wiring
K
it. Allows one single electrical connection for power for BBA/BBC air handlers
and auxiliary electric heater. SPK02A is a "six-pack" of SPK01A.
EHK__A
P1187201C - P1187206C
E
lectric
H
eat
K
it. Auxiliary electric heat for BCA/BHA air handlers
EHK__B/C/D
P1206301C - P1206307C
P1221601C - P1221607C
E
lectric
H
eat
K
it. Auxiliary electric heat for BBA/BBC air handlers
ECB__B/C/D
P1206308C - P1206314C
P1221608C - P1221614C
E
lectric Heat Kit
with
C
ircuit
B
reakers. Auxiliary electric heat for BBA/BBC air handlers. Kit
includes circuit breakers for heaters.
EDB__A
P1235001C - P1235005C
E
lectric Heat "
D
" Series Kit with Circuit
B
reakers. Auxiliary electric heat for BMA air handlers. Kit
includes circuit breakers for heaters.
EDK__A
P1234901C - P1234905C
E
lectric Heat "
D
" Series
K
it. Auxiliary electric heat for BMA air handlers
CCD__A_
P1203914C - P1203916C
C
oil
C
ase Kit ("
D
" design series). Accessory coil case allows installer to add a case to Amana
Uncased up flow/down flow coils, "C" design series and later
DFL01/02
P1232901C - P1232902C
D
own
FL
ow Kit. Contains coil brackets and drain pan for BMA air handlers installed in the down-
flow position
NHK01A
P1235301C
N
o
H
eat
K
it. Contains wiring harness and electric heat blank off plate. Required when installing
the BMA without supplemental electric heat.