P
roduCT
S
PeCifiCATionS
P
roduCT
S
PeCifiCATionS
SS-PTAC50
www.goodmanmfg.com 9
8 www.goodmanmfg.com
SS-PTAC50
PTAC A
CCeSSorieS
(
ConT
.)
STC 30-r
ATing
A
CCeSSory
k
iT
(
noT
SHoWn
)
Raises sound ratings from 27 to 30 to meet or exceed most sound test requirements.
STC101A
10 Pack
H
eATer
k
iT
—f
or
H
eATer
-
leSS
u
niTS
o
nly
(
noT
SHoWn
)
Optional 1.5 kW heater kits are available for use only
with models originally shipped without electric heat. Ask
salesperson for details.
Model Nominal BTUs
230V
208V
265V
Rated Watts
All
1,500
1,200
1,500
Full Load Amps
(incl. fan)
7K & 9K
6.9
6.2
6.1
12K & 15K
7.1
6.4
6.3
Min. Ampacity
7K & 9K
8.6
8.6
7.5
12K & 15K
8.8
8.8
7.7
Fuse Size
All
15
15
15
S
ub
-
bASe
e
xTenSion
C
over
k
iT
Converts older 30-amp sub-bases to allow for installation of the larger 30-amp LCDI power
cord and plugs.
SBEC10A 10 Pack
C
ondenSATe
r
emovAl
P
umP
(
noT
SHoWn
)
Can be field-installed. Assists in removing condensate developed by heat pump operation
and transfers it to indoor coil to dissipate into room while adding humidity to the room.
CDP302 230/208V
CDP402 265V
S
eCuriTy
k
ey
l
oCkS
(
noT
SHoWn
)
In conjunction with the tamper-resistant front, the installation of Amana
®
brand security
key locks prevents tampering of the controls used to set temperature, heating and cooling
functions. UL approved for institutional use only.
KL03B
Security Key Lock
r
ePlACemenT
S
PAre
f
ilTerS
(
noT
SHoWn
)
Helps keep dirt and lint out of the air and off the coil, thus increasing the unit's efficiency.
Amana
®
brand filters are easy to remove, wash, and replace.
FK10A
Filters (10-pack) - A Series
FK10B
Filters (10-pack) - B Series
r
ePlACemenT
C
HArCoAl
f
ilTer
k
iT
(
noT
SHoWn
)
Absorbs airborne odors caused by cigarette, pipe, or cigar smoke and odors caused by
mold, mildew, etc. Filters are made of polyester fibers coated with activated charcoal and
are individually wrapped. These permanent filters can be washed or cleaned and reused.
Call your Amana
®
brand PTAC salesperson for details.
CFK10A
Charcoal Filters - A Series
(10-pack)
CFK10B
Charcoal Filters - B Series
(10-pack)
H
ydroniC
H
eAT
k
iT
Add-on kits fit all units allowing the addition of hydronic water or hydronic steam heat to
cooling and heating units. The kits feature left- or right-hand piping. Unit retains complete
service access with a kit installed. Unit must be connected to and operated by a wall
thermostat.
HWK03
Hydronic Water Kit
HVK03
Hydronic Steam Kit
Unit Controls
Compartment
Hydronic Air
Discharge
5-1/2"
PTAC UNIT WALL SLEEVE
3-1/4"
1-7/8"
3-1/4"
1-7/8"
2-3/4"
2 places
15/32"
2 places
Hydronic Heat Kit-Top View
4-1/8"
Hydronic Front
3"
W
al
l
Sl
ee
ve
Top of Wall Sleeve
Bottom of Wall Sleeve
Toe Plate
0" - 3.0" Long
10-13/16"
+1/8"
-0"
Hydronic Heat Kit-Side View
Hydronic Air
Inlet
8-1/4"
20-3/16"
2-1/8"
53"
Steam/Water
Coil Position
Hot Water Inlet / Outlet Connections
Steam Inlet / Outlet Connection
Hot Water Inlet / Outlet Connections
Steam Inlet / Outlet Connections
16-3/4"
Outlet Connection
Steam Inlet
Hydronic Heat Kit-Right View
H
ydroniC
v
AlveS
(
noT
SHoWn
)
Water and steam valves are available for use with the HWK03
(water) and HVK03 (steam) heat kits. (See Architects and
Engineers Manual for specifications.)
VS2WNCA*
Two-Way / 24-V / NC / Steam
VS2WNOA*
Two-Way / 24-V / NO / Steam
VW2WNCA* Two-Way / 24-V / NC / End Switch
VW2WNOA* Two-Way / 24-V / NO / End Switch
VW3WNC2B*
Three-Way / 24-V / NC / NO / End
Switch
* Pop-top Actuator
H
ydroniC
T
rAnSformer
r
elAy
k
iT
(
noT
SHoWn
)
Add-on kit that allows field conversion of a standard PTC unit to a hydronic unit.
HTK3A 230/208V
HTK4A 265V