4
CONFIGURATION TABLE
* Default Value
Configuration
Code
Configuration Feature Description
Option
Option Code
- -
Menu Start
press Fan button for 1st code
none
Ob
Wired T-stat reversing valve signal (“B” or “O”)
“B” T-stat Terminal
b
“O” T-stat Terminal *
o *
HE
Unit Type
Heat Pump
HP
Cooler with Electric Heat *
EL *
CL
Low Temperature Limited Set Point
60-91°F (but not more than CH); 64°F *
60-90; 64 *
CH
High Temperature Limited Set Point
60-92°F (but not less than CL); 82°F *
60-90; 82 *
db
Auto-Changeover Deadband °C
1.0-2.5, 2.2* °C (1.8-4.5, 4.0* °F)
1.0-2..5, 2.2*
CF
Display °F or °C Temperatures
Fahrenheit Scale *
F *
Celsius Scale
C
LC
Compressor Lockout
Minimum 3-minute Compressor Lockout *
01 *
No Compressor Lockout
00
OC
Occupancy Enable
Enable Occupancy Detection
E
Disable Occupancy Detection *
d *
UC
Un-Occupied Cooling Setpoint
59-92 °F; 82°F *
59-92; 82 *
UH
Un-Occupied Heating Setpoint
58-91 °F; 64°F *
58-91; 64 *
nA
Network Address - Zibee Short Address
Read Only Points
(Press Up Button for) 1st two Hexidedimal Digits
00-FF
(Press Down Button for) 2nd two Hexidedimal Digits
00-FF
Fr
Factory Reset
Reset to Factory Defaults
05
Hold Existing Defaults
00