COOLING PERFORMANCE DA
T
A
70 Rev. 3
EXPANDED PERFORMANCE DATA
COOLING OPERATION
MODEL: RCB/VCB30A2B / CCA30F*A
Outdoor Ambient Temperature
65
75
85
95
105
115
Entering Indoor Wet Bulb Temperature
IDB*
Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
MBh
29.7
30.8
33.7
-
29.0
30.1
32.9
-
28.3
29.3
32.1
-
27.6
28.6
31.4
-
26.2
27.2
29.8
-
24.3
25.2
27.6
-
S/T
0.70
0.59
0.41
-
0.73
0.61
0.42
-
0.75
0.62
0.43
-
0.77
0.64
0.45
-
0.80
0.67
0.46
-
0.81
0.67
0.47
-
Delta T
17
15
11
-
17
15
11
-
17
15
11
-
17
15
11
-
17
15
11
-
16
14
11
-
1125
KW
2.01
2.05
2.13
-
2.18
2.23
2.31
-
2.33
2.38
2.47
-
2.46
2.52
2.61
-
2.57
2.64
2.73
-
2.67
2.74
2.83
-
AMPS
8.9
9.1
9.4
-
9.6
9.9
10.2
-
10.5
10.7
11.1
-
11.2
11.5
11.9
-
12.0
12.2
12.7
-
12.7
13.0
13.4
-
HI PR
149
161
170
-
168
180
190
-
191
205
216
-
217
233
247
-
244
263
277
-
270
290
306
-
LO PR
61
65
71
-
64
68
75
-
67
71
78
-
70
75
81
-
74
78
85
-
76
81
88
-
MBh
28.8
29.9
32.7
-
28.2
29.2
32.0
-
27.5
28.5
31.2
-
26.8
27.8
30.5
-
25.5
26.4
28.9
-
23.6
24.5
26.8
-
S/T
0.67
0.56
0.39
-
0.69
0.58
0.40
-
0.71
0.60
0.41
-
0.74
0.61
0.43
-
0.76
0.64
0.44
-
0.77
0.64
0.45
-
Delta T
18
15
12
-
18
16
12
-
18
16
12
-
18
16
12
-
18
15
12
-
17
14
11
-
70
1000
KW
1.99
2.04
2.11
-
2.16
2.21
2.29
-
2.31
2.36
2.45
-
2.44
2.50
2.59
-
2.55
2.61
2.71
-
2.65
2.71
2.81
-
AMPS
8.8
9.1
9.4
-
9.6
9.8
10.1
-
10.4
10.7
11.0
-
11.1
11.4
11.8
-
11.8
12.1
12.5
-
12.6
12.9
13.3
-
HI PR
148
159
168
-
166
178
188
-
189
203
214
-
215
231
244
-
242
260
275
-
267
287
303
-
LO PR
60
64
70
-
64
68
74
-
66
70
77
-
69
74
81
-
73
77
85
-
75
80
87
-
MBh
26.6
27.6
30.2
-
26.0
26.9
29.5
-
25.4
26.3
28.8
-
24.8
25.7
28.1
-
23.5
24.4
26.7
-
21.8
22.6
24.7
-
S/T
0.65
0.54
0.37
-
0.67
0.56
0.39
-
0.69
0.57
0.40
-
0.71
0.59
0.41
-
0.74
0.61
0.43
-
0.74
0.62
0.43
-
Delta T
18
16
12
-
18
16
12
-
18
16
12
-
18
16
12
-
18
16
12
-
17
15
11
-
875
KW
1.94
1.98
2.05
-
2.10
2.15
2.23
-
2.25
2.30
2.38
-
2.37
2.43
2.52
-
2.48
2.54
2.63
-
2.58
2.64
2.73
-
AMPS
8.6
8.8
9.1
-
9.3
9.5
9.8
-
10.1
10.4
10.7
-
10.8
11.1
11.4
-
11.5
11.8
12.2
-
12.2
12.5
12.9
-
HI PR
143
154
163
-
161
173
183
-
183
197
208
-
208
224
237
-
234
252
266
-
259
279
294
-
LO PR
58
62
68
-
62
66
72
-
64
68
74
-
67
72
78
-
71
75
82
-
73
78
85
-
MBh
30.2
31.1
33.7
36.1
29.5
30.4
32.9
35.3
28.8
29.6
32.1
34.4
28.1
28.9
31.3
33.6
26.7
27.5
29.7
31.9
24.7
25.4
27.5
29.6
S/T
0.80
0.71
0.54
0.35
0.83
0.74
0.56
0.36
0.85
0.76
0.57
0.37
0.88
0.78
0.59
0.38
0.91
0.81
0.62
0.40
0.92
0.82
0.62
0.40
Delta T
20
18
15
10
20
18
15
10
20
18
15
10
20
19
15
10
20
18
15
10
19
17
14
10
1125
KW
2.03
2.07
2.15
2.22
2.20
2.25
2.33
2.41
2.35
2.41
2.49
2.58
2.48
2.54
2.63
2.73
2.60
2.66
2.76
2.86
2.70
2.76
2.86
2.96
AMPS
9.0
9.2
9.5
9.9
9.7
10.0
10.3
10.7
10.6
10.9
11.2
11.6
11.3
11.6
12.0
12.5
12.1
12.4
12.8
13.3
12.8
13.1
13.6
14.1
HI PR
151
162
171
179
169
182
192
201
192
207
219
228
219
236
249
260
247
265
280
292
272
293
310
323
LO PR
61
65
71
76
65
69
75
80
67
72
78
83
71
75
82
88
74
79
86
92
77
82
89
95
MBh
29.3
30.2
32.7
35.1
28.6
29.5
31.9
34.2
28.0
28.8
31.2
33.4
27.3
28.1
30.4
32.6
25.9
26.7
28.9
31.0
24.0
24.7
26.7
28.7
S/T
0.76
0.68
0.52
0.33
0.79
0.71
0.53
0.34
0.81
0.72
0.55
0.35
0.84
0.75
0.57
0.36
0.87
0.78
0.59
0.38
0.88
0.78
0.59
0.38
Delta T
21
19
15
11
21
19
16
11
21
19
16
11
21
19
16
11
21
19
16
11
19
18
15
10
75
1000
KW
2.01
2.06
2.13
2.20
2.18
2.23
2.31
2.39
2.33
2.38
2.47
2.56
2.46
2.52
2.61
2.70
2.57
2.64
2.73
2.83
2.67
2.74
2.83
2.94
AMPS
8.9
9.1
9.4
9.8
9.6
9.9
10.2
10.6
10.5
10.8
11.1
11.5
11.2
11.5
11.9
12.3
12.0
12.2
12.7
13.2
12.7
13.0
13.4
13.9
HI PR
149
161
170
177
168
180
190
199
191
205
217
226
217
234
247
257
244
263
277
289
270
290
307
320
LO PR
61
65
71
75
64
68
75
79
67
71
78
83
70
75
81
87
74
78
85
91
76
81
88
94
MBh
27.1
27.9
30.2
32.4
26.4
27.2
29.5
31.6
25.8
26.6
28.8
30.9
25.2
25.9
28.1
30.1
23.9
24.6
26.6
28.6
22.1
22.8
24.7
26.5
S/T
0.73
0.66
0.50
0.32
0.76
0.68
0.52
0.33
0.78
0.70
0.53
0.34
0.81
0.72
0.55
0.35
0.84
0.75
0.57
0.36
0.84
0.75
0.57
0.37
Delta T
21
19
16
11
21
19
16
11
21
19
16
11
21
20
16
11
21
19
16
11
20
18
15
10
875
KW
1.96
2.00
2.07
2.14
2.12
2.17
2.25
2.33
2.27
2.32
2.40
2.49
2.40
2.45
2.54
2.63
2.50
2.56
2.66
2.75
2.60
2.66
2.76
2.86
AMPS
8.7
8.9
9.2
9.5
9.4
9.6
9.9
10.3
10.2
10.5
10.8
11.2
10.9
11.2
11.6
12.0
11.6
11.9
12.3
12.8
12.3
12.6
13.1
13.6
HI PR
145
156
165
172
163
175
185
193
185
199
210
219
211
227
239
249
237
255
269
281
262
282
297
310
LO PR
59
63
69
73
62
66
72
77
65
69
75
80
68
72
79
84
71
76
83
88
74
78
86
91
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA (TVA) conditions