13 Rev. 3
CONDENSING UNIT SPECIFICATIONS
IMPORTANT NOTE:
WHILE THIS DATA IS PRESENTED AS A GUIDE, IT IS IMPORTANT TO ELECTRICALLY CONNECT THE UNIT
AND PROPERLY SIZE WIRES AND FUSES/CIRCUIT BREAKERS IN ACCORDANCE WITH THE NATIONAL
ELECTRICAL CODE AND/OR LOCAL CODES.
MODEL
RCE60
A2A
RCE60
A2B
COOLING CAPACITY, BTUH
58000
58000
COMPRESSOR
R.L. AMPS
25.0
25.0
L.R. AMPS
169.0
169.0
CONDENSER FAN MOTOR
HORSEPOWER
1/4
1/4
R.L. AMPS
2.1
2.1
L.R. AMPS
3.7
3.7
LIQUID LINE, INCHES O.D.
3/8
3/8
SUCTION LINE, INCHES O.D.
1 1/8
1 1/8
REFRIGERANT CHARGE
250.0 oz.
250.0 oz.
POWER SUPPLY
208/230-60-1
208/230-60-1
MIN.CIRCUIT AMPACITY
33.4
33.4
MAX. OVERCURRENT
DEVICE
55
55
ELECT. CONDUIT SIZE
POWER SUPPLY
1/2" or 3/4"
1/2 or 3/4
LOW VOLTAGE
1/2"
1/2
APPROX. SHIPPING WT
314
314
MODEL
VCA18
B2A
VCA24
B2A
VCA30
B2A
VCA36
B2A
VCA36
B3A
VCA42
B2A
VCA48
B2A
VCA48
B3A
COOLING CAPACITY, BTUH
18000
24000
30000
36000
36000
42000
48000
48000
COMPRESSOR
R.L. AMPS
9.0
10.9
13.7
15.3
8.9
18.1
23.1
12.8
L.R. AMPS
48.3
60.0
69.4
84.0
63.4
97.6
110.0
90.0
CONDENSER FAN MOTOR
HORSEPOWER
1/12
1/12
1/5
1/4
1/4
1/4
1/4
1/4
R.L. AMPS
0.6
0.6
1.6
1.7
1.7
1.7
1.7
1.7
L.R. AMPS
1.2
1.2
3.1
3.7
3.7
3.7
3.7
3.7
LIQUID LINE, INCHES O.D.
0.25
0.25
3/8
3/8
3/8
3/8
3/8
3/8
SUCTION LINE, INCHES O.D.
5/8
5/8
3/4
3/4
3/4
7/8
7/8
7/8
REFRIGERANT CHARGE
46.0 oz.
63.0 oz.
67.0 oz.
78.0 oz.
78.0 oz.
83.0 oz.
108.0 oz.
108.0 oz.
POWER SUPPLY
208/230-60-1
208/230-60-1
208/230-60-1
208/230-60-1
208/230-60-3
208/230-60-1
208/230-60-1
208/230-60-3
MIN.CIRCUIT AMPACITY
12.0
14.4
18.7
20.8
12.8
24.3
30.6
17.7
MAX. OVERCURRENT
DEVICE
20
25
30
35
20
40
50
30
ELECT. CONDUIT SIZE
POWER SUPPLY
1/2" or 3/4"
1/2" or 3/4"
1/2" or 3/4"
1/2" or 3/4"
1/2" or 3/4"
1/2" or 3/4"
1/2" or 3/4"
1/2" or 3/4"
LOW VOLTAGE
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
APPROX. SHIPPING WT
144
145
149
168
168
187
200
200