5-9
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
CAPACITOR
HIGH VOLTAGE
DIODE
NOTE :
Some inexpensive meters
may indicate infinite
resistance in both direction.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to terminal.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to case.
Measure the continuity (Forward).
(Ohm-meter scale: Rx10000)
Measure the continuity (Reverse).
(Ohm-meter scale: Rx10000)
Normal: Momentarily indicates
several ohms, and then
gradually returns to
infinite.
Normal: Infinite.
Normal: Infinite.
Abnormal: Continuity.
Normal: Continuity.
Abnormal: Infinite.
NOTE: When testing the magnetron, be sure to install the magnetron gasket
in the correct position and be sure that the gasket is in good condition.
5-9
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
CAPACITOR
HIGH VOLTAGE
DIODE
NOTE :
Some inexpensive meters
may indicate infinite
resistance in both direction.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to terminal.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to case.
Measure the continuity (Forward).
(Ohm-meter scale: Rx10000)
Measure the continuity (Reverse).
(Ohm-meter scale: Rx10000)
Normal: Momentarily indicates
several ohms, and then
gradually returns to
infinite.
Normal: Infinite.
Normal: Infinite.
Abnormal: Continuity.
Normal: Continuity.
Abnormal: Infinite.
NOTE: When testing the magnetron, be sure to install the magnetron gasket
in the correct position and be sure that the gasket is in good condition.
5-9
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
CAPACITOR
HIGH VOLTAGE
DIODE
NOTE :
Some inexpensive meters
may indicate infinite
resistance in both direction.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to terminal.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to case.
Measure the continuity (Forward).
(Ohm-meter scale: Rx10000)
Measure the continuity (Reverse).
(Ohm-meter scale: Rx10000)
Normal: Momentarily indicates
several ohms, and then
gradually returns to
infinite.
Normal: Infinite.
Normal: Infinite.
Abnormal: Continuity.
Normal: Continuity.
Abnormal: Infinite.
NOTE: When testing the magnetron, be sure to install the magnetron gasket
in the correct position and be sure that the gasket is in good condition.
5-9
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
CAPACITOR
HIGH VOLTAGE
DIODE
NOTE :
Some inexpensive meters
may indicate infinite
resistance in both direction.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to terminal.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to case.
Measure the continuity (Forward).
(Ohm-meter scale: Rx10000)
Measure the continuity (Reverse).
(Ohm-meter scale: Rx10000)
Normal: Momentarily indicates
several ohms, and then
gradually returns to
infinite.
Normal: Infinite.
Normal: Infinite.
Abnormal: Continuity.
Normal: Continuity.
Abnormal: Infinite.
NOTE: When testing the magnetron, be sure to install the magnetron gasket
in the correct position and be sure that the gasket is in good condition.
Antenna
Gasket
Chassis
Filament
Antenna
Gasket
Chassis
Filament
Antenna
Gasket
Chassis
Filament
Antenna
Gasket
Chassis
Filament
Antenna
Gasket
Chassis
Filament
Antenna
Gasket
Chassis
Filament
Antenna
Gasket
Chassis
Filament
Antenna
Gasket
Chassis
Filament
Summary of Contents for LD510D
Page 8: ...SCHEMATIC DIAGRAM 4 2 ...
Page 24: ...6 1 EXPLODED VIEW INTRODUCTION EV MODEL LD510D ...
Page 25: ...6 2 DOOR PARTS 1007 1006 1013 1004 2385 2384 1005 EV ...
Page 26: ...6 3 CONTROL PANEL PARTS 2007 2005 2003 W109 2015 2386 W102 2002 2014 EV ...
Page 27: ...6 4 OVEN CAVITY PARTS 01 7037 3001 W108 W118 3009 W105 5024 EV ...
Page 28: ...6 5 LATCH BOARD PARTS W102 4002 4003 4002 4000 4001 EV ...
Page 30: ...6 7 BASE PLATE PARTS 5008 6000 W115 6007 W108 W101 6001 EV ...