WARNING

To avoid death or personal injury due to electrical shock, disconnect the electrical power before performing any
maintenance.

Routine Maintenance

If you perform maintenance on the furnace yourself, remember that certain mechanical and electrical knowledge, skills
and tools are required to perform maintenance on the furnace.  Personal injury or death my result.  If you are not
properly trained.  You should call your installing dealer or place of purchase if you are uncertain about your ability to
perform maintenance.

Annual Inspection

The furnace should be inspected by a qualified installer, or service agency at least once per year.  This check should
be performed at the beginning of the heating season.  This will insure that all furnace components are in proper working
order and that the heating system functions appropriately.  Particular attention should be paid to the following items.
Repair as necessary.

• Flue pipe system.  Check for blockage and/or leakage.  Check

the outside termination and the connections at and internal to the
furnace.

• Heat exchanger.  Check for corrosion and/or buildup within the

heat exchanger passageways.

• Burners.  Check for proper ignition, burner flame, and flame

sense.  Flames should extend directly outward from burners with-
out curling, floating or lifting off.

• Drainage system.  Check for blockage and/or leakage.  Check

hose connections at furnace.

• Wiring.  Check electrical connections for tightness and/or corro-

sion.  Check wires for damage.

• Filters.  Check that filters are clean and in the proper placement

in the furnace or duct system.

Check the burner flames for: 
1. Good adjustment
2. Stable, soft and blue 

3. Not curling, floating, or lifting off. 

Burner Flame

Summary of Contents for GULA

Page 1: ...omfort Quality Trust Heating Air Conditioning GULA Gas Fired Warm Air Furnace User s Information Manual 10318826 October 2002 You have purchased a high efficiency gas fired warm air residential furnac...

Page 2: ...Single Pipe 6 Flue Pipe and Condensate Drainage 7 Indoor Humidity 7 For Propane LP Gas Installations Only 8 Operating Your Furnace 9 Furnace Operation 9 Thermostat Functions 9 Integrated Control Modu...

Page 3: ...PERSONNEL As a professional installer you have an obligation to know the product better than the customer This includes all safety precautions and related items Prior to actual installation thoroughly...

Page 4: ...ection Inlets Alternate 17 CoilFrontCoverPressureTap 18 Coil Front Cover Drain Port 19 DrainLinePenetrations 20 DrainTrap 21 Blower Door Interlock Switch 22 Capacitor 23 IntegratedControlModule with f...

Page 5: ...safe and dependable service providing it is properly installed and main tained However abuse and or improper use can shorten the life of the furnace and create hazards for you the home owner WARNING T...

Page 6: ...s produced when fuel is not burned completely or when the flame does not receive sufficient oxygen Be aware of these air starvation signals which indicate conditions that may result in carbon monox id...

Page 7: ...ure Example At 40 relative humidity the air could hold 2 1 2 times as much moisture 2 5 x 40 100 before becoming saturated The colder the air the less moisture it can hold As air is warmed its ability...

Page 8: ...nace is installed in a basement an excavated area or a confined space it is strongly recommended to contact a propane supplier to install a gas detecting warning device in case of a gas leak Since pro...

Page 9: ...ype allows for a different temperature at night or during the day when no one is at home Programmable thermostats will allow for more control and tailoring of the heating and cooling functions The lev...

Page 10: ...e ON OFF switch to the ON position 9 Replace the burner compartment door 10 Open the external manual gas shut off valve 11 Turn on the electrical power to the furnace 12 Adjust the thermostat to a set...

Page 11: ...eat exchanger the rollout limit will detect it and shutdown gas flowing to the burners Pressure Switches The pressure switches are normally open closed during operation single pole single throw negati...

Page 12: ...ce components are in proper working order and that the heating system functions appropriately Particular attention should be paid to the following items Repair as necessary Flue pipe system Check for...

Page 13: ...ons will use a ductwork or central return grille location To remove filter s from the ductwork or central return grille installation 1 Turn off electrical power to the furnace 2 Remove filter s from d...

Page 14: ...Check to see that the manual gas shut off valve external to the furnace is in the ON position If the valve is in the OFF position turn the gas ON following the start up procedures outlined in the Star...

Page 15: ...iance if any part has been underwater Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been underwat...

Page 16: ...erage Most questions can be answered by your local Amana dealer If you need further information regarding the operation maintenance or service of your furnace contact your dealer If you have other mat...

Page 17: ...17...

Page 18: ...18 is a trademark of Maytag Worldwide N V and is used under license to Goodman Company L P All rights reserved...

Reviews: