IMPORTANT SAFETY INFORMATION
SAVE THESE INSTRUCTIONS
2000
Amana Appliances
Amana, Iowa 52204
Part No. 36-31971301-0
Printed in U.S.A. 02/00
Minimum Clearances to Combustible Surfaces
Underwriter’s Laboratories, Inc. specifies this range can
be installed flush against right and left base cabinets, and
rear vertical wall. Range can also be installed flush
against left or right vertical wall extending above 36 inch
standard countertop height. The dimensions provided
are to be measured from the range itself, and not the
installation cutout for the range.
A—Minimum of 30 inches between top of cooking surface
and bottom of an unprotected wood or metal cabinet.
OR
A—Minimum of 24 inches between cooking surface and
protected wood or metal cabinet above range. Cabinet
bottom must be protected by at least ¼ inch thick
millboard with not less than No. 28 MSG sheet steel, .015
inch thick stainless steel, .024 inch thick aluminum, or
.020 inch thick copper.
B—Minimum of 30-inches of protected cabinets above
range (refer to letter A)
C—Minimum of 18” between top of countertop and bottom
of an unprotected wood or metal cabinet.
D—Maximum depth of 13” for overcounter cabinets.
WARNING
!
To reduce the risk of the appliance tipping, it must be secured by a
properly installed anti-tip bracket(s). To make sure bracket has been
installed properly, remove the storage drawer or panel and look
under the range with a flashlight. Bracket(s) must be engaged in the
rear corner of the range.
WARNING
!
To avoid risk of burns or fire by
reaching over elements, cabinet
storage space located above
range should be avoided. If
cabinet storage is provided,
install a range hood that projects
horizontally a minimum of 5
inches beyond the cabinet
bottom to reduce the risk.
WARNING
!
To avoid risk of electrical shock,
personal injury, or death, make
sure your range has been
properly grounded and always
disconnect it from main power
supply before servicing.
• ALL RANGES CAN TIP
• INJURY TO PERSONS
COULD RESULT
• INSTALL ANTI-TIP
BRACKET(S) PACKED
WITH RANGE
• SEE INSTALLATION
INSTRUCTIONS
A
B
C
D