Amana DigiSmart PTC073G***XXX Product Specifications Download Page 3

P

roduct

 S

PecificationS

SS-DPTAC

www.amana-ptac.com

3

P

roduCT

 s

PeCifiCATions

:  PTC m

odels

 — C

ooling

/e

leCTriC

 H

eAT

230/208 V

olts

Model 

PTC

073G***XXX

PTC

093G***XXX

PTC

123G***XXX

PTC

153G***XXX

Voltage ³

230 / 208

230 / 208

230 / 208

230 / 208

Capacity (BTU/h)

7,700

9,000

11,700 / 11,500

15,000 / 14,700

Amps

 

¹⁰

3.5

4.1

5.6

7.0

Watts

 

¹⁰

670/660

805/785

1135/1105

1500/1470

EER

11.5/11.7

11.2/11.5

10.3/10.4

10.0/10.0

Unit without Electric Heater

Min. Circuit Amps ²

,

 ⁴

,

 ¹⁰

4.2

4.9

6.8

8.5

CFM (Cool/Wet Coil)

High

290

290

290

340

Low

264

264

264

314

CFM (Dry Coil)

High

310

310

310

360

Low

282

282

282

332

Ventilated Air, CFM (Fan Only)*

65*

65*

65*

65*

Dehumidification (Pints/Hr.)

1.7

2.2

3.6

4.4

Net Weight (lbs.)

98

102

102

113

Ship Weight (lbs.)

113

117

119

130

265/277 V

olts

Model 

1, 6, 8

PTC

074G***XXX

PTC

094G***XXX

PTC

124G***XXX

PTC

154G***XXX

Voltage ¹

³

265

265

265

265

Capacity (BTU/h)

7,700

9,000

12,000

14,800

Amps

 

¹⁰

3.0

3.6

4.8

6.0

Watts

 

¹⁰

670

795

1,165

1,480

EER

11.5

11.3

10.3

10.0

Unit without Electric Heater

Min. Circuit Amps ²

,

 ⁴

,

 ¹⁰

3.6

4.4

5.9

7.4

CFM (Cool/Wet Coil)

High

290

290

290

340

Low

264

264

264

314

CFM (Dry Coil)

High

310

310

310

360

Low

282

282

282

332

Ventilated Air, CFM (Fan Only)*

65*

65*

65*

65*

Dehumidification (Pints/Hr.)

1.7

2.2

3.6

4.4

Net Weight (lbs.)

98

102

102

113

Ship Weight (lbs.)

113

117

119

130

* Actual vent CFM performance will vary due to application and installation conditions.
Notes
¹  All 265-volt models must use an Amana® brand sub-base (PTSB4**E) or an Amana® brand hard-wire kit PTPWHWK4 and disconnect switch PSHW04A.
²  Minimum Circuit Ampacity (MCA) ratings conform to the National Electric Code; however, local codes should apply. 
³  Minimum voltage on 230/208-volt models is 197 volts; maximum is 253 volts. Minimum voltage on 265-volt models is 239 volts; maximum is 292 volts. 
⁴  Overcurrent protection for all units without electric heaters is 15 amps. Overcurrent protection on 265-volt models must be cartridge-style time-delay fuses (included and 

factory-installed on all Amana® brand 265-volt chassis). See heater performance 

⁵  Heating capacity and efficiency based on unit operation without condensate pump; unit automatically switches to electric heat at approximately 24°F outdoor ambient.
⁶  Specify two-digit heater kW size to complete model number.
⁷  R-410A refrigerant used in all systems.
⁸  All units meet or exceed ASHRAE 90.1 standards.
⁹  All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards.
¹⁰   Refer to electric heat performance data for total MCA and recommended overcurrent protection. Amps and Watts notation refers to compressor only.

Summary of Contents for DigiSmart PTC073G***XXX

Page 1: ...es condensate from indoor cooling operation and evaporates it into the atmosphere through the condenser Digismart front desk control energy management software Room freeze protection is activated when...

Page 2: ...TU h 50 Hz H Hydronic Heat Capable 12 12000 BTU h 50 or 60 Hz P Condensate Pump PTH Only 15 14000 BTU h 60 Hz Q Quiet STC 31 Chassis Rated Voltage R RF Antenna 2 115V 60 Hz 1 Ph V Power Vent 3 230 208...

Page 3: ...7 2 2 3 6 4 4 Net Weight lbs 98 102 102 113 Ship Weight lbs 113 117 119 130 Actual vent CFM performance will vary due to application and installation conditions Notes All 265 volt models must use an...

Page 4: ...142 Actual vent CFM performance will vary due to application and installation conditions Notes All 265 volt models must use an Amana brand sub base PTSB4 E or an Amana brand hard wire kit PTPWHWK4 Mi...

Page 5: ...volts have a Leak Current Detector Interrupter LCDI power cord and meet UL 484 standards Product Specifications PTH Models Reverse Cycle Heating Performance Heating Capacity PTH073G AXXX PTH093G AXXX...

Page 6: ...ally sealed internally isolated rotary type and permanently mounted on rubber isolators No removal or adjustment of compressor hold down bolts is to be required during installation Warranty Thewarrant...

Page 7: ...er Vent Damper Must be provided to maximize ventilation air intake to up to approximately 95 CFM Power vent must be off and damper door closed when unit fan is de energized Fuse Holder included in 265...

Page 8: ...lters 1 Facing the unit pull up on the filter handles located at the front top of the unit 2 Pull each filter upward and remove 3 Clean filters with vacuum or with running water Reverse this procedure...

Reviews: